Sign In
Upload
Manuals
Brands
Viessmann Manuals
Heat Pump
AWT-AC 221.A13
Viessmann AWT-AC 221.A13 Manuals
Manuals and User Guides for Viessmann AWT-AC 221.A13. We have
3
Viessmann AWT-AC 221.A13 manuals available for free PDF download: Installation And Service Instructions Manual, Installation And Service Instructions For Contractors
Viessmann AWT-AC 221.A13 Installation And Service Instructions For Contractors (140 pages)
Compact heat pumps, split version for heating and cooling operation
Brand:
Viessmann
| Category:
Heat Pump
| Size: 17.49 MB
Table of Contents
Index Index
4
Table of Contents
4
Information Disposal of Packaging
6
Symbols
6
Intended Use
6
Product Information
7
Preparing for Installation Requirements for On-Site Connections
8
Recommended Power Cables
9
Installation Sequence Installing the Outdoor Unit
11
Installation Information
11
Installation Site
12
Minimum Clearances
12
Transport and Siting
13
Floorstanding Installation
14
Wall Mounting
14
Installing the Indoor Unit
14
Transport
14
Installation Room Requirements
15
Minimum Clearances
16
Removing the Cylinder Module
17
Assembly and Sealing Faces to Note
21
Connecting the Refrigerant Lines
23
Routing the Refrigerant Lines
23
Sound and Vibration Isolation When Line Entry Is above Ground Level
24
Connection to Outdoor Unit
25
Connection to Indoor Unit
26
Connecting the Secondary Circuit
29
Connecting the DHW Side
31
Safety Valve
31
Type AWT-AC Only: Connecting the Cooling Circuit
31
Electrical Connection
32
Indoor Unit: Routing Cables to the Wiring Chamber
33
Indoor Unit: Overview of Connections
34
Indoor Unit: Main PCB (230 V~ Components)
35
Indoor Unit: Expansion PCB on Main PCB (230 V~ Components)
37
Indoor Unit: Luster Terminals (Signal and Safety Connections)
37
Indoor Unit: Controller and Sensor PCB (LV Connections)
38
Indoor Unit: AVI PCB
39
Outdoor Unit: Overview of Connections
40
Connecting Indoor and Outdoor Units
41
Power Supply
41
Heat Pump Control Unit Power Supply 230 V
42
Outdoor Unit Power Supply 230 V~/400 V
42
Connecting Instantaneous Heating Water Heater Power Supply
44
Power Supply with Power-OFF: Without On-Site Load Disconnect
44
Power Supply with Power-OFF: with On-Site Load Disconnect
45
Mains Power Supply in Conjunction with On-Site Power Consumption
47
Smart Grid
47
Closing the Heat Pump
48
Fitting the Side Cover for the Outdoor Unit
48
Commissioning, Inspection, Maintenance Steps - Commissioning, Inspection and Maintenance
49
Commissioning, Inspec-Steps - Commissioning, Inspection and Maintenance
49
Opening the Heat Pump
50
Compiling Reports
50
Purging the Refrigerant Lines and Indoor Unit
50
Checking the Refrigerant Lines for Leaks
50
Evacuating the Refrigerant Lines and Indoor Unit
51
Charging the Refrigerant Lines and Indoor Unit
52
Checking the Refrigerant Circuit for Tightness
53
Filling and Venting the Secondary Side
53
Checking the Expansion Vessel and Heating Circuit Pressure
55
Cleaning the DHW Cylinder
55
Measuring the Anode Earth Current with an Anode Tester
56
Checking the Magnesium Anode
56
Replacing the Magnesium Anode
56
Checking the Indoor Unit Electrical Connections for Firm Seating
57
Checking the Fan in the Outdoor Unit Can Run Freely
57
Cleaning the Outdoor Unit Heat Exchanger (Evaporator)
57
Checking the Thermal Insulation of Flared Connections
58
Starting the Heat Pump
58
Commissioning the System
59
Ticking the Heat Pump Type
65
Switching on the Power Supply
58
Checking Electrical Connections of the Outdoor Unit for Firm Seating
58
Closing the Heat Pump
58
Checking the Heat Pump for Noise
65
Checking the System Function
65
Instructing the System User
66
Maintenance Overview of Electrical Components
67
Opening Programming Unit
67
Overview of Internal Components: Indoor Unit
69
DHW Cylinder Drain & Fill Valve Positions
70
Overview of Internal Components: Outdoor Unit
70
Outdoor Unit 4 Kw, Type AWT/AWT-AC 221.A04
71
Outdoor Unit 5 to 7 Kw, Type AWT/AWT-AC 221.A05/A07
72
Outdoor Unit 10 to 16 Kw, Type AWT/AWT-AC 221.A10/A13, 221.B10 to B16
73
Draining Secondary Side Heat Pump
73
Checking the Sensors
74
Indoor Unit: Viessmann NTC 10 K Ω
74
(Marked Blue)
74
Indoor Unit: Viessmann Pt500A (Green ID Label)
75
Outdoor Unit: NTC 10 K Ω
75
(Without ID)
75
Outdoor Unit: NTC 50 K Ω
76
Checking the Fuses
76
(Without ID)
76
Overview of Assemblies, Indoor Unit
78
Indoor Unit Parts Not Shown
79
Indoor Unit Casing
80
Indoor Unit Electrical Equipment
82
Indoor Unit Hydraulics
84
Indoor Unit Cylinder
88
Ordering Parts
91
Outdoor Unit Parts 230 V~, Type AWT/AWT-AC 221.A04
92
Ordering Parts
95
Outdoor Unit Parts 230 V~, Type AWT/AWT-AC 221.A05/A07
96
Overview of Assemblies 230 V~, Type AWT/AWT-AC 221.A10/A13
99
Outdoor Unit Casing 230 V~, Type AWT/AWT-AC 221.A10/A13
100
Outdoor Unit Electrical Equipment 230 V~, Type AWT
102
Awt-Ac 221.A10/A13
102
Outdoor Unit Hydraulics 230 V~, Type AWT/AWT-AC 221.A10/A13
104
Overview of Assemblies 400 V~, Type AWT/AWT-AC 221.B10/B13/B16
107
B10/B13/B16
107
Outdoor Unit Casing 400 V~, Type AWT/AWT-AC 221.B10/B13/B16
108
Outdoor Unit Electrical Equipment 400 V~, Type AWT/AWT-AC 221.B10/B13/B16
110
B10/B13/B16
110
Outdoor Unit Hydraulics 400 V~, Type AWT/AWT-AC 221.B10/B13/B16
112
Hydraulic Parameter Report
114
Control Parameter Report
115
Commissioning Order
129
13. Appendix Final Decommissioning and Disposal
129
Declaration of Conformity
130
Advertisement
Viessmann AWT-AC 221.A13 Installation And Service Instructions Manual (164 pages)
Compact heat pumps, split version for heating and cooling operation
Brand:
Viessmann
| Category:
Heat Pump
| Size: 17.22 MB
Table of Contents
Index Installation Instructions
4
Table of Contents
4
Preparing for Installation
6
Intended Use
6
Requirements Regarding On-Site Connections
7
Installing the External Unit
10
Installing the Internal Unit
15
Connecting the Refrigerant Lines
24
Connecting the Secondary Circuit
34
Connecting the DHW Side
37
Connecting a Cooling Circuit if Required
38
Electrical Connection
38
Power Supply
54
Closing the Heat Pump
62
Steps - Commissioning, Inspection and Maintenance
63
Commissioning, Inspection, Maintenance
63
Commissioning Steps
64
Inspection Steps
64
Maintenance Steps Page
64
Compiling Reports
65
Further Details Regarding the Individual Steps
65
Opening the Heat Pump
65
Evacuating the Refrigerant Lines and Internal Unit
66
Filling the Refrigerant Lines and Internal Unit
69
Checking the Refrigerant Circuit for Tightness
70
Filling and Venting the Secondary Side
71
Checking Expansion Vessel and Heating Circuit Pressure
73
Cleaning the DHW Cylinder
74
Checking the Free Running of the Fan in the External
76
Cleaning the External Unit Heat Exchanger (Evaporator)
76
Replacing the Magnesium Anode
76
Unit
76
Checking Electrical Connections of the External Unit
77
For Firm Seating
77
Commissioning the System
78
Starting the Heat Pump
78
Repairs
89
Troubleshooting
89
Ordering Parts
101
Parts Lists, Internal Unit
101
Overview of Assemblies, Internal Unit
102
Casing, Internal Unit
103
Parts Not Shown, Internal Unit
103
Electrical Equipment, Internal Unit
105
Hydraulics, Internal Unit
108
Cylinder, Internal Unit
111
Ordering Parts
113
Parts Lists, External Unit 230 V~, Type AWT-AC 221.A04
113
External Unit 230 V
114
Parts Lists, External Unit 230 V~, Type AWT-AC 221.A07
114
External Unit 230 V
115
Parts Lists, External Unit 230 V~, Type AWT-AC
115
Ordering Parts
116
Overview of Assemblies 230 V
121
Casing, External Unit 230 V
122
Electrical Equipment, External Unit 230 V
124
Hydraulics, External Unit 230 V
126
Ordering Parts
127
Parts Lists, External Unit 400 V~, Type AWT-AC 221.B10, B13
127
Overview of Assemblies 400 V
129
Casing, External Unit 400 V
130
Electrical Equipment, External Unit 400 V
132
Hydraulics, External Unit 400 V
134
Commissioning/Service Reports
135
Control Parameters Report
135
Hydraulic Parameter Report
135
Specification
144
Appendix
153
Commissioning Order
153
Declaration of Conformity
154
Keyword Index
155
Viessmann AWT-AC 221.A13 Installation And Service Instructions Manual (156 pages)
Compact heat pumps, split version for heating and cooling operation
Brand:
Viessmann
| Category:
Heat Pump
| Size: 17.32 MB
Table of Contents
Table of Contents
61
Opening the Heat Pump
63
Compiling Reports
63
Evacuating the Refrigerant Lines and Internal Unit
64
Filling the Refrigerant Lines and Internal Unit
66
Checking the Refrigerant Circuit for Tightness
68
Filling and Venting the Secondary Side
68
Checking Expansion Vessel and Heating Circuit Pressure
71
Cleaning the DHW Cylinder
72
Replacing the Magnesium Anode
74
Checking that Condensate Can Drain Away Freely from the External Unit Condensate Pan 14. Checking the Free Running of the Fan in the External Unit
74
Cleaning the External Unit Heat Exchanger (Evaporator)
74
Checking Thermal Insulation of Flared Connections 17. Checking Electrical Connections of the External Unit for Firm Seating
75
Starting the Heat Pump
76
Commissioning the System
76
Checking the System Function
85
Temperatures, Heat Meter if Applicable)
85
Instructing the System User
86
Advertisement
Advertisement
Related Products
Viessmann VITOCAL AWOT-E 221.A
Viessmann AWT-AC 221.A04
Viessmann AWT-AC 221.A05
Viessmann AWT-AC 221.A07
Viessmann AWT-AC 221.A10
Viessmann BWT-M 221.A06
Viessmann BWT-M 221.A08
Viessmann AWT-AC 221.B13
Viessmann AWT-AC 221.B16
Viessmann AWBT-M 221.C04
Viessmann Categories
Boiler
Toy
Control Unit
Heat Pump
Solar panel
More Viessmann Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL