New Holland SmartTrax T8.320 Service Manual page 54

Hide thumbs Also See for SmartTrax T8.320:
Table of Contents

Advertisement

During the inlet phase, the quantity of fuel flow to the pumping element is determined by the regulating valve. The
regulating valve, dependent on the PWM command sent from the ECU, meters the fuel to the pumping elements.
When the pumping element starts decreasing the volume the inlet valve will close. The fuel is now trapped in the
pumping chamber and the pressure will start to build. When the pressure in the pumping chamber becomes higher
than the pressure in the common rail the outlet valve will open the fuel will flow to the common rail.
(1) Fuel to common rail
(2) Outlet valve
(3) Pumping element
(4) Eccentric pump shaft
Engine - Engine and crankcase
38
RAIL15TR01379GA
(5) PWM metered fuel
(6) Low pressure supply fuel
(7) Regulator valve (PWM)
47917992 25/09/2015
10.1 [10.001] / 27

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smarttrax t8.350Smarttrax t8.380Smarttrax t8.410Smarttrax t8.435Zfre03123T8.320 ... Show all

Table of Contents