Fault Codes - Viessmann Vitodens 333 Service Instructions Manual

Compact gas fired condensing boiler. 4.2 to 19 kw natural gas and lpg version
Hide thumbs Also See for Vitodens 333:
Table of Contents

Advertisement

Troubleshooting
Calling up fault codes from the fault memory (fault . . .
Press the following keys:
1. G + d simultaneously for
approx. 2 s.

Fault codes

Display
Const.
Weath.
fault
comp.
code
0F
X
X
10
X
18
X
20
X
X
28
X
X
72
2. a/b
3.
Note
All saved fault codes can be
deleted with e.
4. d
System char-
Cause
acteristics
Control mode
Maintenance Service the equip-
Regulates as
Outside tem-
if the outside
perature
temperature
sensor
was 0 °C
shorted out
Regulates as
Outside tem-
if the outside
perature
temperature
sensor lead
was 0 °C
broken
Regulates
Flow tem-
without flow
perature
temperature
sensor low
sensor (low
loss header
loss header)
shorted out
Regulates
Low loss
without flow
header flow
temperature
temperature
sensor (low
sensor break
loss header)
(cont.)
for individual fault
codes.
terminate the scan.
Remedy
ment. After the
service, set code
"24:0".
Check the outside
temperature sen-
sor (see page 80)
Check the outside
temperature sen-
sor (see page 80)
Check the low
loss header flow
temperature sen-
sor (see page 81)
Check the low
loss header flow
temperature sen-
sor (see page 81)