Page 1
FT...-74G... FT...-76G... FT...-78G.. FT...-712G... FT...-712G...3 FT...T-74G... FT...T-76G... FT...T-78G... FT...T-712G... FT...T-712G...3 Model LIBR.ISTR.FT70G Code 563006901 Review 1 Edition date 19/09/2018 Language English LOTUS S.p.A. Via Calmaor, 46 31020 San Vendemiano +39 0438 778020 +39 0438 778277 Translation of the original instructions...
Contents Contents INTRODUCTION ......................... Installation drawing ........................Components..........................Example installation of the appliance................... GENERAL INFORMATION......................Declaration of compliance......................Technical data table ........................INSTALLATION........................... Delivery checks ..........................Removing the packaging ......................Mechanical installation ......................... Electrical/gas connections ......................BURNERS TECHNICAL DATA TABLE (ITGB)................Burners technical data table ......................
INTRODUCTION Components FIG. A 1 Valve knob 2 Dashboard bracket 3 Piezoelectric 4 Valve 5 Gas pipes 6 Extends drainage 7 Pilot 8 Ignition spark plug 9 Injector 10 Bracket 11 Fat collection pan Translation of the original instructions...
Page 6
INTRODUCTION FIG. B A Piezoelectric FIG. C 1 Bracket 2 Pilot light nozzle 3 Ignition spark plug 4 Extends drainage Translation of the original instructions...
GENERAL INFORMATION 2 GENERAL INFORMATION Declaration of compliance The manufacturer declares that the appliances comply with the requirements of the regulation GAR 2016/426 for the gas part and directive 2014/30/EU,2014/35/EU for the electrical part. Installation must be performed in compliance with current regulations, especially with regard to ventilation of the premises and the exhaust gas evacuation system.
GENERAL INFORMATION Technical data table Technical data table FT S70G GAS FITTING RATED MODEL DIMENSIONS ISO 7-1 TOTAL GAS FLOW (kW) FT*-74G*** 40x70x90h R ½GM FT*T-74G*** 40x70x29h R ½GM FT**-76G*** 60x70x90h R ½GM 10,5 FT**T-76G*** 60x70x29h R ½GM 10,5 FT**-78G*** 80x70x90h R ½GM FT**T-78G***...
INSTALLATION 3 INSTALLATION Delivery checks On delivery, it is important to check the following: · External conditions of the packaging · The general status of the equipment · The conformity of the model with the information in the technical data plate and the instruction manual ·...
Page 11
INSTALLATION Installation operations, any conversion to other types of gas and start-up must only be performed by qualified personnel, in accordance with current regulations. Gas systems, electrical connections and premises where the appliances are installed must comply with current regulations in the country of installation;...
Page 12
INSTALLATION For burners equipped with air adjustment, set the adjustable bushing and lock it with a screw. The "Burner technical data" table shows approximate values for the "h" parameter (primary air). The primary air flow volume must be adjusted to avoid a flame cut-off when the burner is cold and a flame blowback when the burner is hot.
Page 13
INSTALLATION Forced evacuation (fig.4) The gas supply to the appliance must be directly servo-controlled by the forced evacuation system and must stop if the flow rate drops below the values indicated in point 4.3 of the UNI-CIG 8723 standard. Resetting the gas supply to the appliance must be possible only by hand.
INSTRUCTIONS FOR USE 5 INSTRUCTIONS FOR USE General information This appliance must only be used for its expressly intended purpose for cooking or heating food. Any other use is considered improper. The appliance is also intended for industrial use and must only be used by personnel trained for use and aware of the risks that the hot element entails.
INSTRUCTIONS FOR USE Switching the appliance off · Press and turn the knob to position "0". This control blocks the gas supply to both the main burner and the pilot burner Emptying the container This rack should be checked regularly and emptied before it is full. In any case, the rack must be cleaned after switching off the appliance ...
MAINTENANCE 6 MAINTENANCE Routine When using the appliance over time, it is essential to perform regular maintenance to ensure safe operation. We therefore recommend stipulating a service contract. Caution Maintenance must only be performed by specialist personnel in compliance with current ...
MAINTENANCE Warning After conversion to another type of gas, update the technical data plate to indicate the type of gas for which the appliance has been converted. Spare parts It is possible to replace parts such as the valve, the piezoelectric or the ignition control unit (depending on the type of appliance) or the gas pipes easily and quickly.
CLEANING 7 CLEANING Routine cleaning Caution The use of flammable fluids to clean the appliance is forbidden To ensure hygiene and the durability of the appliance, perform external cleaning on a regular basis, taking care not to damage the cables and the electrical connections. Before starting cleaning, disconnect the appliance from the power supply.