Mobile radio:
Supported fre-
E-GSM-900
quency bands
DCS-1800
Radiated maximum transmitting
power:
E-GSM-900:
880 - 915 MHz:
33.0 dBm
DCS-1800:
1,710 -
1,785 MHz:
30.0 dBm
Docking station ADO 601:
Voltage U
42 V
DC
Protection class
III
Type of protection
IPX1
Weight
3 kg
Perimeter wire and guide loop:
Frequency range
1.0 kHz - 90 kHz
Maximum field
strength
< 72 µA/m
Power supply unit:
Voltage U
100 - 240 V
AC
Frequency
50/60 Hz
Voltage U
42 V
DC
Protection class
I
Type of protection
IP67
Transporting STIHL batteries:
STIHL batteries meet the requirements
specified in UN manual
ST/SG/AC.10/11/Rev.5 Part III,
subsection 38.3.
The user may carry STIHL batteries to the
place of use of the machine without further
restrictions during road transport.
Country-specific legislation must be
observed in the case of air or sea
transport.
72
For further transport instructions, see
http://www.stihl.com/safety-data-sheets
REACH:
REACH is an EC Directive for the
registration, evaluation, authorisation and
restriction of chemicals. For information on
compliance with the REACH Directive
(EC) No. 1907/2006, see
www.stihl.com/reach

23. Messages

Messages provide information on
active errors, faults and
recommendations. They are
displayed in a dialog window and can be
called up after pressing the OK button in
the "Messages" menu. (
Recommendations and active messages
also appear on the status screen. (
The message code, the time of
occurrence, the priority and the frequency
of occurrence can be called up in the
message details.
– Recommendations are awarded
the priority "Low" or "Info"; they
appear in the status screen alternately
with the text "iMow ready for op.".
The robotic mower can still be
operated, automatic operation
continues.
– Faults are awarded the priority
"Medium" and require action on the
part of the user.
The robotic mower can only be
operated again once the fault has been
rectified.
– In the case of errors awarded the
priority "High", the text "Contact
your specialist dealer" appears on the
display.
The robotic mower can only be
operated again once the fault has been
rectified by a STIHL specialist dealer.
11.9)
11.2)
Message:
0001 – Data updated
Press OK to release
Possible cause:
– The machine software has been
updated
– Voltage loss
– Software or hardware error
Remedy:
– After the OK button is pressed, the
robotic mower operates with the default
settings – check and correct the
settings (date, time, mowing plan)
If a message is still active despite
the proposed remedial action,
please contact your STIHL
specialist dealer.
Faults that can only be rectified by
a STIHL specialist dealer are not
listed in the following. Should a fault
of this kind occur, please
communicate the 4-digit fault code
and the fault text to your specialist
dealer.
RMI 632 C, RMI 632 PC:
Messages that impair normal
operation are also reported to the
app. (
10.)
The robotic mower enters standby
after the message is sent and
disables radio communication to
preserve the battery.