Translation of original operating manual Technical product information TPI 1140 EN Hydraulically released brake 0128-...-..-...000 series Keep for future use Ortlinghaus-Werke GmbH Postfach 50 14 40 42907 Wermelskirchen Kenkhauser Str. 125 42929 Wermelskirchen Germany Tel. +49 2196 85-0 +49 2196 855-444 Email info@ortlinghaus.com...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN Table of contents 1. Notes regarding use of the operating manual 9. Servicing and repair, modifi cation 1.1. Who are the operating instructions aimed at? 9.1. Hazard notes on servicing and repairs 1.2. What can be found in the operating instructions? 4 9.2.
OI or TPI via the internet from the “Service” directory at www. ortlinghaus.com. You are also free to make copies of this example. Always keep the OI near to the machine or system in order to ensure direct acces- sibility.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 1.2. What can be found in the operating instructions? These OI with the product drawing contain all the necessary information related to the product named on the cover page for the proper utilisation throughout the various stages of operation.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN WARNING! • Hazard while performing the described activity or as a result of non- observance of explosion protection during machine operation. ➜ Potentially severe head injury. 1.4.2. Product / machinery / plant system damage CAUTION! •...
Any other use or use going beyond the use described in the chapter “Intended purpose” and “Proper use” is considered to be improper use. Ortlinghaus is not liable for damages arising from this. Especially, but not exclusively, improper use of our product includes: ➜...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 2.4. Functional description CAUTION! ➜ Never operate the brake at a higher pressure, as otherwise there is a risk of shearing screws. The normal opening pressure is 50 + 5 bar, maximum permissible pres- sure is 60 bar.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 2.5. Brake with backup actuation Model serie 0128- . 5 to 0128- . 8 (⇨ 2.5.1 “Brake with backup actuation” on page 9) Fig. 2: function of the brake with backup actuation 2.5.1. Brake with backup actuation The piston 5 is impinged with pressure oil via the connection 1 (piston chamber 8) and the braking torque is raised.
3. Transport, packaging The delivery is to be checked for transport damage and any apparent defi ciencies upon receipt. In the event of damage, inform Ortlinghaus accordingly. Only products that are in technically fl awless condition are to be installed or commissioned.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 3.3. Transport Only use lifting gear with suffi cient load capacity for transportation. Observe the following instructions for transportation. WARNING! • Load the transport threads uniformly and only in a vertical direction. ➜ Pay attention to the load bearing capacity of the lifting accessories.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 4. Installation and assembly instructions The supplier or operator is responsible for the installation of the product described. Comply with the applicable regulations and requirements as well as these OI. Check the operational readiness before installation. Use appropriate lifting gear for handling whilst the installation work is being carried out.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 4.3. Installation Body of machine Housing bolts Inkremental sender (optional) Drive shaft Actuation unit Oil drain back Brake housing Locking bolts Pick-up bolts Fig. 4: Installing the brake Fig. 5: Installation of the brake with backup actuation...
Page 15
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN • Unscrew brake housing from the actuator unit and bolt and pin onto the machine body. • Fix the hub to the shaft. Ensure that the axial position is correct! When fi xing with a tensioning set, observe the manufacturer's installation instructions and remove any plastic plugs! •...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 5. Commissioning Prior to commissioning, the connection on the drive side and output side must be checked for correct attachment and a functional test carried out. Furthermore, a functional test must also be carried out after maintenance or repair with a stationary system or machine.
Page 17
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN Remedial actions, safety Hazard Cause Effects information Assembly/pressure system: Machine move- Running over, Check installation position in accordance Infl uencing of the effective- ment sliding away, with drawing, secure inner drive in axial...
When initially commissioning of the system the basic contamination must be fi ltered out before releasing the brake for the fi rst time. When operating with Ortlinghaus hydraulic-components, the discharge cock of the accumulator group should be opened and the hydraulic system run for approx.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 6. Operation No liability is assumed for completeness with regard to the guidance and safety instructions contained within these OI. Observe the system docu- mentation for the complete machine for start-up, operation, maintenance, repair and shut-down.
Page 20
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN Remedial actions, safety Hazard Cause Effects information Thermal hazards: Dynamic switching processes, Objects or mate- Burning Operator instructions, clearance grille or high speeds, excessive oil rials with high/low temperature sensor, observe oil fi ll quantity/...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 6.2. Inspection while the machine is in operation The brake is largely wear- and maintenance-free. Incorrect operation (oil pressure too low, operating temperature too high, excessive switching frequency etc.) can however still result in wearing of the plates. Plate wear shows itself in changed operating behaviour of the brake : The braking angle increases, i.e.
➜ Make sure therefore that operation is correct to prevent further wear. • In the case of functional faults, the product is to be sent back to the Ortlinghaus-Werke for inspection or alternatively arrange for our trained fi tters to perform an inspection on site.
• The product can be a safety-relevant part that may present a hazard potential that should not be underestimated if not properly maintained. ➜ If the function is impaired, we recommend a replacement or Ortlinghaus customer service. We accept no liability for damage or operational inter- ruption caused by improperly executed maintenance works.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN Remedial actions, safety Hazard Cause Effects information Hazards in connection with the operational environment of the machine Disassembly/assembly or with Impurities, dust, Stumbling, falling When working, ensure that working surface other miscellaneous work...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN The maximum possible air measurement (max. value ) determine the design-based piston stroke. In the normal running-in procedure for the friction surfaces an extension of the opening travel by approx. 0.05 mm per friction surface may occur (after running-in process).
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 8.5. Care Our products are to be protected against corrosion in accordance with their conditions and location of use. Remove loose dirt, corrosion, and deposits of dust or dirt. Do not use a pressure washer or agents which may damage the corrosion protection or parts of the product.
9. Servicing and repair, modifi cation 9.1. Hazard notes on servicing and repairs NOTE! ➜ Only Ortlinghaus customer service department or personnel trained and authorised by Ortlinghaus are permitted to carry out servicing and repairs! Remedial actions, safety Hazard Cause...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 9.2. Disassembly WARNING! When working on the product ensure that it is not possible for any uninten- tional machine movements to occur by disabling the function:, ➜ Drive the press ram to the bottom dead centre.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 9.3. Size and tightening torque of the screws WARNING! ➜ Secure all screw connections against loosening independently, e.g. with Loctite type 262 and observe the prescribed tightening torques. (For numbering, see (⇨ 10.2 “Cutaway” on page 33))
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 9.4. Hazard notes on modifi cation NOTE! ➜ Only Ortlinghaus customer service department or personnel trained and authorised by Ortlinghaus are permitted to carry out modifi cations! Remedial actions, safety Hazard Cause Effects...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 10. Spare parts Please also quote the serial number when ordering replacement parts. This is located on the outside at the position marked with the arrow. The production number comprises a two-digit year number and a serial number, e.g.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 10.1. Parts list (see cutaways) Item Individual part 10.10 Piston 10.40 Hexagonal bolt 10.50 Disc 10.60 Cylinder head bolt 10.70 Cylinder head bolt 10.80 Cylinder head bolt 10.90 Sealing ring 10.100 Rectangular ring 10.110...
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 11. Storage, de-commissioning 11.1. Hazard notes on storage, de-commissioning Remedial actions, safety Hazard Cause Effects information Mechanical hazards: Removal -> Product under Gravity/spring Crushing, Observe instructions in OI, disassembly spring pressure force (stored catching, only by suffi...
➜ Free from aggressive and corrosive substances such as solvents. With longer storage times suitable measures for additional corrosion protection should be implemented following consultation with Ortlinghaus. 11.3. De-commissioning Prior to commencing with the de-commissioning of our product refer to the general operating instructions for the system or machine.
Ortlinghaus-Werke GmbH Operating instructions TPI 1140 EN 12. Disposal The product consists of different materials, which can either be reused or disposed of separated by type. Disassemble the product and separate the individual parts by material type. The individual parts are to be disposed of in accordance with the stipula-...