MAINTENANCE

ATTENTION
Maintenance of the appliance must be carried out
Unscrew
when the machine is switched off and unplugged.
Approximately every 100 hours of operation, or
every 6 months, wash the boiler using an appro-
E
priate scale removing product available on the
market (follow the instructions given by product
manufacturer). Carry out the following procedure:
a) Remove the fill-up cap (E) (Fig. 32).
b) Unscrew the drain cap (36) (fig. 33); drain the boiler
Fig. 32
and tighten the cap again.
c) Fill the boiler with the scale removing liquid
NOTE
Before removing the drain cap (36) position a bowl
under the appliance to collect drain water.
d) Leave the scale removing product in the boiler for as
long as indicated in the product instructions.
36
e) Unscrew the drain cap (36) (Fig. 33) and let the scale
remover out. Rinse the boiler repeatedly until the scale remo-
Fig. 33
ving product is eliminated completely.
f) Tighten the cap (36) again (Fig. 36). If you want to fill
the boiler with water, follow the instructions given on page 27
under section "Preparing the appliance ready for use".
CAUTION
Use only steam boiler-specific cleaning products.