D Type I Wiring Diagram; E Inspection And Maintenance Interval - Vaillant atmoMAG MAG mini 114/1 I Installation And Maintenance Instructions Manual

Table of Contents

Advertisement

Appendix
D
Type I wiring diagram
1
19
15
16
14
1
Gas valve assembly
2
Micro switch
3
Monitoring electrode
4
Ignition electrode
5
Burner
6
Transparent connection cable
7
Blue connection cable
8
Safety cut-out
9
Flue gas sensor
10
Red connection cable
E
Inspection and maintenance interval
The table below lists the manufacturer requirements with respect to minimum inspection and maintenance intervals. If na-
tional regulations and directives require shorter inspection and maintenance intervals, you should observe these instead of
the intervals listed. Each time inspection and maintenance work is carried out, carry out the required preparatory and com-
pletion work.
#
Maintenance work
1
Remove any dirt from the product
2
Check the flue gas sensor for dirt and damage. Checking that the flue
gas sensor is working correctly by completely blocking the flue gas with
flue gas restrictors
3
Checking the safety cut-out for dirt and damage
22
2
18
17
13
12
11
11
12
13
14
15
16
17
18
19
Installation and maintenance instructions atmoMAG 0020273765_00
3
4
5
6
7
10
Electronics box
Yellow connection cable
Black connection cable
1 x 1.5 V
Red connection cable
Black connection cable
Blue connection cable
Orange connection cable
Green connection cable
Interval
Annually
Annually
Annually
8
9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents