Is a continuous indicator of the current levels of ec, ph and temperature, enabling you to optimise these parameters as your crop progresses through each growing phase (16 pages)
The Bluelab Powerpod is an electronically controlled mains switching box that is designed to ® ™ activate mains powered equipment via control signals from a Bluelab control device. The Bluelab ® ® Powerpod is ideal for use when using a Bluelab Pro Controller with third party mains powered ™...
1.4 Product documentation Documentation for this product consists of a printed user manual that is supplied with the product as well as being available electronically from the Bluelab website: bluelab.com ® This documentation contains the latest product safety information at the time of publication. The information in this documentation is subject to change.
IEC 61010-1:2010 ® ™ standard, and has been supplied as new, in a safe condition. This manual contains information and warnings that must be observed to keep the Bluelab ® Powerpod in a safe condition and ensure safe operation.
It a two-conductor mains power cable is used, or if this Bluelab® Powerpod™ is connected to a non-grounded power outlet then ensure that the equipment connected to the Bluelab® Powerpod™ does not require a ground connection.
To avoid possible electric shock, personal injury or death, only use the factory supplied cables to connect to external devices. CAUTION To avoid possible damage to the Bluelab® Powerpod™ ensure that the total maximum load of the connected external equipment is not more that 8.5 Amps. Connect external equipment into one or all four of the power sockets on the Bluelab ®...
® ™ • Never get water inside this product. • Only use factory supplied mains cables, replacements can be purchased from bluelab.com If the Bluelab Powerpod requires cleaning, ® ™ wipe it with a cloth that is lightly dampened with water or a mild detergent.
3.2 Replacing a faulty fuse WARNING To avoid possible electric shock, personal injury or death, in the event that the internal fuse needs replacing, first check the external equipment, Bluelab Powerpod cabling and connectors for signs ® ™ of damage or electrical faults, and repair/replace as required before replacing the internal fuse.
4.0 Troubleshooting & Specifications 4.1 Troubleshooting guide WARNING To avoid possible electric shock, personal injury or death, disconnect the Bluelab Powerpod ® ™ from the mains power source before performing any maintenance. TROUBLE REASON CORRECTION Check that all connectors are fully Connectors are not fully inserted.
Powerpod to a Bluelab ® ™ ® Why would I want to use the Bluelab ® Controller that already has dosing pumps will add the Powerpod when I already have a ability to control reservoir temperature. This can be done ™...
Output Sockets Mains Power Input Control Input Control Output (to Doser) (to Next) Bluelab Powerpod output sockets ® ™ Type IEC C13 female mains OUTPUT socket Output voltage range 110 - 240 V~ (same as input voltage applied at 4)
PPCNA shown above Dosing cable Bluelab Dosing cable ® Part number: 500005 Fuse Fuse can be replaced by ordering from Bluelab, or one of the suggested manufacturers: Bluelab Fuse ® Part number: 660055 Manufacturer - Cooper Bussmann Manufacturer part number: S505-10-R Manufacturer - Littelfuse Manufacturer part number: 0215010.MXP...
This warranty is governed by the laws of the state of country where Product is purchased, without regard to its choice of law principles. Except as allowed by law, Bluelab does not limit or exclude other rights a consumer may have with regard to the Product.
Need help?
Do you have a question about the CTRL50110 and is the answer not in the manual?
Questions and answers