    Care and use guide Contents page Features Bluelab pH Probe Preparing for use Important Bluelab pH Probe care 3 Calibration Cleaning the pH probe Storing the pH probe Hydrating the pH probe Technical specifi cations Troubleshooting guide Bluelab pH Probe care...
  • Page 2: Features

    Glass tube inside plastic barrel pH probe storage cap The pH probe tip must not be allowed to dry out. Always place the storage cap back onto the pH probe after each use. Ensure the cap contains enough Bluelab pH Probe KCl Storage Solution to cover the probe tip.
  • Page 3: Preparing For Use

    DO NOT last forever. They age through normal use and will eventually fail. The life time of a pH probe depends on the environment it is used in and the way that it is treated. To receive a long life from your pH probe, please ensure you follow the guide below.
  • Page 4: Calibration

    See section 4.0 (the pH probe does not require cleaning before the fi rst use). Calibrate the pH. This must be done before the pH probe is used for the fi rst time. Follow the calibration instructions on the back of the meter, in the manual or watch our videos online.
  • Page 5: Cleaning The Ph Probe

    Cleaning the Bluelab pH Probe To ensure accurate readings the pH probe tip needs to be rinsed in water after each use and cleaned prior to calibration using the following instructions. The storage cap must always be put back on after cleaning. Always ensure it contains enough Bluelab pH Probe KCl Storage Solution to cover the probe tip.
  • Page 6: Hydrating The Ph Probe

    Hydrating the pH probe Hydrate the pH probe in Bluelab pH Probe KCl Storage Solution when: • the probe tip has not always been stored in KCl storage solution, to improve the reading response speed. • the probe tip has been accidentally allowed to dry out.
  • Page 7: Troubleshooting Guide

    Calibrate using two points - 7.0 pH, then 4.0 pH or 10.0 pH. pH calibration unreliable Calibrate pH probe. pH probe damaged or old. Replace pH probe. Verify by removing the sample Ground loop (often occurs from its environment then take...
  • Page 8: Bluelab Ph Probe Care

    Solution The perfect solution to store and hydrate your Bluelab pH products. Bluelab pH Probe KCl Storage Solution is designed to increase response time and maximize the life of Bluelab pH pens and pH probes. For best results, use the KCl solution for storage of the pH probe.
  • Page 9: Limited Product Guarantee

    If any part is no longer available or out of manufacture, Bluelab will replace it with a functionally- equivalent replacement part.