IMPORTANT SAFETY INFORMATION WARNING - This shower can deliver scalding temperatures, cause fire, electric shock or other personal injury if not operated, or maintained in accordance with the instructions, warnings and cautions contained in this guide and on the appliance. Please read the important safety information and the operation section of this guide before using the shower.
Page 3
21. DO NOT connect the outlet of the shower to any tap, control valve, trigger operated handset or showerhead other than those specified for use with this shower as the outlet acts as a vent for the tank body. Only Kohler Mira recommended accessories should be used. 1079320-W2-G...
22. DO NOT perform any unspecified modifications, or drill or cut holes in the product other than instructed by this guide. When servicing only use genuine Kohler Mira replacement parts. 23. Always check the water temperature is safe before entering the shower. 24. The water supplies to this product must be isolated if the product is not to be used for a long period of time.
Page 5
INTRODUCTION The Mira GO Manual Power Shower is an all-in-one power shower with an integral mains voltage pump, and separate controls for flow and temperature. It features a 15 mm dual entry push-fit manifold which supports various inlet supply configurations. The manifold includes inlet filters and check valves. Designed to be surface mounted, the Mira GO Manual Power Shower comes complete with an adjustable spray handset with three settings, flexible hose, adjustable slider, sliding rail, soap tray and bracket. Guarantee For domestic installations, Mira Showers guarantee the Mira GO Manual Power Shower against any defect in materials or workmanship for a period of one year from the date of purchase (shower fittings for one year).
PACK CONTENTS Tick the appropriate boxes to familiarise yourself with the part names and to confirm that the parts are included. 1 x Manual Power Shower 4 x Case Inserts 1 x Flow Control Knob 1 x Installation and User Guide 1 x Temperature Indicator Trim ...
Page 7
DIMENSIONS All dimensions are nominal and in millimetres. 1079320-W2-G...
Maximum maintained pressure: 50 kPa (0.5 bar) Maximum static pressure: 100 kPa (1 bar) or 10 m head of water Duty Cycle: The Mira GO Manual Power Shower pump is now continuously rated. The motor is fitted with a self-resetting thermal trip, designed to operate if motor temperatures become too high due to abnormally high supply voltages.
INSTALLATION REQUIREMENTS Gravity Fed System - The shower MUST be fed from a cold water cistern and hot water cylinder providing nominally equal pressure. 90° 25 mm Min 30° - 60° Cistern Service Valve 10 m Maximum 80 mm Minimum 1 m Head Minimum Vent...
INSTALLATION General Do not take risks with plumbing or electrical equipment. Do not install the shower unit in a position where it could become frozen. Isolate electrical and water supplies before proceeding with the installation of the shower unit. The shower unit must be fed from a cold water storage cistern and hot water cylinder with equal pressures.
Page 11
Plumbing A minimum storage capacity of cold water of 230 litres (50 gallons) is required to provide adequate showering time. Insufficient storage may result in the pump being run dry. Layout and sizing of pipework must be such that nominally equal inlet supply pressures are achieved and the effects on the shower performance of other draw-offs are minimised. Make sure the shower unit is the first draw-off from the water supply. Avoid routing the high level hot feed pipe upward to the same level as the cold tank e.g.
Page 12
Warning! Do not fix the shower unit to the wall until plumbing and electrical installations have been completed. Decide on a suitable location for the shower unit avoiding buried cables and pipes. The unit should be positioned at a height convenient for all the family (at least 200 mm below the ceiling to allow for the fitting and removal of the unit cover).
Page 13
Make sure that the end of the supply Chamfer pipework is cut squarely and is free from burrs, which will damage the inlet manifold seals. Chamfer the end of the pipe to assist insertion into the fitting and prevent the ‘O’ seal tearing. Warning! Do not insert fingers into the push-fit connectors as this can result in injury.
Page 14
Temporarily locate the shower unit. Position the shower unit on the wall and mark the three fixing points. Note! Installers may wish to obtain alternative proprietary cavity fixings for dry lined, stud partition or dry partition wall structures. 9. Use the push-fit release tool to push the grey collars into the manifold to release the shower unit from the supply pipes.
Page 15
12. Fit the three rubber feet into the Rubber Feet recesses in the rear of the case as shown. The feet will reduce the noise transmitted by the power shower through the wall. Warning! Blanking plates should be fitted to stop water ingress into the inside of the unit. 13.
Page 16
14. Locate the shower unit on the inlet supplies and push the inlet manifold onto the pipework until resistance is felt. DO NOT FORCE! Note! PTFE tape or liquid jointing compound must not be used and is not required to assist connection. 15.
Page 17
19. Refit the unit cover and secure with the three cover securing screws. OFF Position 20. Insert the flow control knob in the OFF position. 21. Insert the temperature indicator trim and the inner temperature control knob. Flow Control Knob Arrow/OFF Position Temperature Indicator Trim Inner Temperature Control Knob 22.
Page 18
COMMISSIONING The unit must not be run dry. Before proceeding any further with the installation the shower unit must be commissioned. 1. Connect the flexible hose to the outlet of the shower unit. Hose Washer Caution! Do not over tighten. Hose Turn on the water supplies and check for leaks.
OPERATION Warning! The shower is a manual mixing shower which can select water temperatures from FULL HOT to FULL COLD. If the temperature control knob is turned anticlockwise fully the shower will deliver water at the same temperature as the stored hot water temperature (this will be the same temperature as the hot tap water temperature).
FAULT DIAGNOSIS Fault Diagnosis - User Maintenance The appliance is fully performance tested after assembly. Providing it has been correctly installed and is operated as advised, difficulties should not arise. In the unlikely event that you experience problems with your appliance then the following procedure will enable you to undertake basic fault finding before contacting the person responsible for installing your shower.
Page 21
Fault Diagnosis - Installer Maintenance The Manual Power Shower is one part of an entire plumbing system. The fitting of a pump places additional requirements on the plumbing system. Some systems may require plumbing modifications to allow them to cope with higher flow rates. Providing the Manual Power Shower has been correctly installed and is operated as advised, difficulties should not arise. Fault diagnosis and maintenance must be carried out by a competent person for whom the fault diagnosis table is provided. In the event of any of the following tests failing, re-check as appropriate before contacting the Customer Support Department, (refer to the Back Cover).
Page 22
Malfunction Cause Remedy Maximum shower Hot water cylinder Adjust cylinder temperature. temperature too temperature too low. Note! The stored water cold. temperature must not exceed 65 °C. The blend The spray plate is blocked. Clean the spray plate. Refer temperature to the supplied shower unstable.
MAINTENANCE Warning! There are no user serviceable components beneath the cover of the appliance. Only a competent tradesperson should remove the cover. Before removing the cover the electricity supply must be turned off at the mains and, if applicable, the appropriate circuit fuse removed. Mains electrical connections are exposed when the cover is removed.
Page 25
ACCESSORIES Genuine Mira accessories can be purchased direct from Customers Services (our contact details can be found on the back cover of this guide) or from approved stockists or merchants. Shower Seat Premium Shower Seat White - 2.1536.128 White/Chrome - 2.1731.001 White/Chrome - 2.1536.129 Grey/Chrome - 2.1731.002 For use in or out of the showering...
Need help?
Do you have a question about the mira GO and is the answer not in the manual?