6. Gently push the chair over onto the footrest, turn it upside down or, gently push it over onto its side,
opposite of the hand control.
7. Unplug the transformer and the hand control extension from the motor (or control box.)
8. Remove the eight (8) T30 lag screws that hold the lift frame to the arm assembly.
9. Remove the hitch pin(s), the clevis pin(s), and the washers that fasten the
recline bar.
10. Remove the hand control extension wire clamp.
11. Lift the lift frame out of the chair shell and place it off to the side.
12. Use the 3/8 in. socket to remove the four (4) bolts that fasten each scissor mechanism to the arm
assembly.
While this next step can be done alone, it does require extra attention. You must
remove the arm assembly without twisting the frame. Excessive twisting will cause the board
holding the arms together to snap.
13. Stand behind the chair and pull the arms away from the chair being careful not to get the material
snagged in the scissor mechanisms.
14. Place the arm assembly to the side.
15. Use the
Phillips
footboard.
16. Use the 3/8 in. socket to remove the bolts that fasten the scissor mechanism to the seat and to the
footboard.
17. Use the 3/8 in. socket to install the bolts that fasten the new scissor mechanism to the seat and the
footboard.
18. Use the
Phillips
footboard.
19. Place the arm assembly in place so that the bolt holes in the scissor mechanisms line up with the bolt
holes in the armrest.
20. Install the four (4) bolts that fasten each scissor mechanisms to the arm assembly.
21. Make sure the footboard is completely closed.
Note: When installing the lift frame the footboard must be completely closed when you fasten the lift
frame to the armrest assembly or the footboard will not close properly.
22. Place the lift frame onto the chair shell.
23. Use the hitch pin(s), the clevis pin(s), and the washers to fasten the
bar.
24. Use the eight (8) T30 lag screws to fasten the lift frame to the arm assembly.
25. Reinstall the hand control extension wire clamp.
26. Plug the transformer and hand control extension into the motor or control box.
27. Plug the battery backup back into the transformer.
28. Plug the transformer back into the wall outlet and test.
29. Reinstall the seatback (if removed).
Recline Bar Replacement
Tools needed: Needle nose pliers, P2 Phillips screwdriver, T30 screw bit, wire cutters, zip ties, 3/8 in.
socket, a stool or stand for placing the chair upside down.
1.
Unplug the transformer from the wall outlet.
2. Unplug the battery backup cable from the transformer.
screwdriver to remove the screws that fasten the scissor mechanism to the
screwdriver to install the screws that fasten the new scissor mechanism to the
REVA_082012
recline
strap(s) to the
recline
strap(s) to the recline
12