18 Troubleshooting

18 Troubleshooting
18.1
Troubleshooting Trimmer
Condition
Trimmer does not
start when switched
on.
Trimmer cuts out dur‐
ing operation.
Mowing head cannot
be unscrewed by
hand.

19 Specifications

19.1
STIHL FSE 52 Trimmer
– Supply voltage: 220-240 V
– Frequency: 50/60 Hz
– Rated current: 2.3 A
– Fuse: 10 A
– Power consumption: 500 W
– Rated speed under load: 6000 rpm
Weight with deflector ad cutting attachment
– Version with 0.3 m cable: 2.2 kg
– Version with 9.9 m cable: 2.8 kg
– Electrical protection class: II
19.2
Extension Cords
If an extension cord is used, it must have a
ground wire and the wire gage of its conductors
must meet the following minimum requirements –
0458-777-0121-D
Cause
Connecting cable plug or extension
cable plug not connected.
Miniature circuit breaker (fuse) or
ground fault circuit interrupter has trip‐
ped. Circuit is overloaded or faulty.
Wall outlet's fuse rating is too low.
Wire gauge of extension cable is
wrong.
The extension cable is too long.
Connecting cable plug or extension
cable plug has been pulled out of wall
outlet.
Miniature circuit breaker (fuse) or
ground fault circuit interrupter has trip‐
ped. Circuit is overloaded or faulty.
Wall outlet's fuse rating is too low.
Mowing head overtightened.
Remedy
► Reconnect connecting cable plug or
extension cable plug.
► Determine reason for circuit breaker
tripping and rectify the problem.
Switch on miniature circuit breaker
(fuse) or ground fault circuit inter‐
rupter.
► Switch off other consumers in the
same circuit.
► Insert the connecting cable plug in a
wall outlet with the correct fuse rat‐
ing,
19.1.
► Use an extension cable of the right
wire gauge.
► Use an extension cable of the cor‐
rect length,
► Reconnect connecting cable plug or
extension cable plug.
► Determine reason for circuit breaker
tripping and rectify the problem.
Switch on miniature circuit breaker
(fuse) or ground fault circuit inter‐
rupter.
► Switch off other consumers in the
same circuit.
► Insert the connecting cable plug in a
wall outlet with the correct fuse rat‐
ing,
19.1.
► Block the fanwheel with the stop pin.
► Unscrew mowing head by hand.
► Remove stop pin.
depending on the line voltage and length of the
extension cord:
If rated voltage on the rating label is 220V to
240V:
– Cord length up to 20 m: AWG 15 / 1.5 mm²
– Cord length 20 m up to 50 m: AWG 13 /
2.5 mm²
If rated voltage on the rating label is 100 V to
127 V:
– Cord length up to 10 m: AWG 14 / 2.0 mm²
– Cord length 10 m up to 30 m: AWG 12 /
3.5 mm²
19.3
Noise and Vibration Data
K-value (uncertainty) for sound pressure levels is
2 dB(A). K-value (uncertainty) for sound power
English
19.2
19.2
13