Download Print this page
Trotec SL800-SET Operating Manual

Trotec SL800-SET Operating Manual

Ultrasonic detector
Hide thumbs Also See for SL800-SET:

Advertisement

Quick Links

SL800-SET
EN
OPERATING MANUAL
ULTRASONIC DETECTOR

Advertisement

loading

Summary of Contents for Trotec SL800-SET

  • Page 1 SL800-SET OPERATING MANUAL ULTRASONIC DETECTOR...
  • Page 2: Table Of Contents

    Technical data). • Do not expose the device to directly squirting water. • Check accessories and connection parts for possible damage prior to every use of the device. Do not use any defective devices or device parts. ultrasonic detector SL800-SET...
  • Page 3: Information About The Device

    Information about the device To use the device for its intended use, only use accessories and spare parts which have been approved by Trotec. Device description Foreseeable misuse The measuring device serves the purpose of detecting the...
  • Page 4 Signal input and connection for probe SL800T (ultrasonic transmitter) Designation Airborne sound probe Adapter Headphones Jack plug Volume control for headphones Structure-borne sound probe Designation Battery compartment with cover Transmitter for ultrasonic signal (40 kHz) Operating control lamp On/off switch ultrasonic detector SL800-SET...
  • Page 5: Transport And Storage

    • For storing the device, use the transport case included in several metres. the scope of delivery in order to protect the device from external influences. • the storage temperature complies with the values specified in the Technical data ultrasonic detector SL800-SET...
  • Page 6 For that reason always set the volume control at the headphones to minimum before starting a measurement (narrow end of the wedge at the volume control). Increase the volume only slowly. If necessary, reduce the volume when approaching a potential ultrasound source. ultrasonic detector SL800-SET...
  • Page 7 ü The volume control at the headphones is set to minimum. 1. Put on the headphones. 2. Test the volume by rubbing the fingertips of thumb and index finger against one another at a distance of approx. 50 cm from the airborne sound probe. ultrasonic detector SL800-SET...
  • Page 8 (e.g. a tank). 2. Press the Power button (9) on the SL800T. 3. Shut the object properly. 4. Switch on the SL800R using the thumbwheel (3). 5. Put on the headphones. ultrasonic detector SL800-SET...
  • Page 9: Errors And Faults

    • In addition, carefully increase the volume at the receiver (if necessary). ð The operating control lamp (8) goes out. ð The SL800T is switched off. ultrasonic detector SL800-SET...
  • Page 10: Maintenance And Repair

    EU countries on the website Do not modify the device or install any spare parts. For repairs https://hub.trotec.com/?id=45090. Otherwise, please contact an or device testing, contact the manufacturer. official recycling centre for electronic and electrical equipment Battery change authorised for your country.
  • Page 11 Trotec GmbH Grebbener Str. 7 D-52525 Heinsberg +49 2452 962-400 +49 2452 962-200 info@trotec.com www.trotec.com...

This manual is also suitable for:

3510002000