Float Switch Wiring; Alert Light Mounting - Aprilaire E080CS Installation And Operation Manual

Hide thumbs Also See for E080CS:
Table of Contents

Advertisement

FLOAT SWITCH WIRING

If using a condensate pump, remove the factory installed jumper
wire between the FLOAT SWITCH terminals on the control, and wire
the float switch terminals to the normally closed contacts on the
condensate pump or float switch . See Figure 10 .

ALERT LIGHT MOUNTING

1. Locate the alert light mounting bracket where it will be readily
visible .
2. Run the ALERT LIGHT to the mounting bracket and clip it in the
bracket as shown in Figure 11 . Use the provided plastic wire
staples to secure the wire in place .
NOTE: The alert light does not need to be installed for the unit to
function .
FIGURE 10 – Float Switch Wiring
LOW VOLTAGE
NORMALLY CLOSED
CONTACTS ON
CONDENSATE PUMP
FIGURE 11 – Alert Light Mounting
AMBER LIGHT
MOUNTING
BRACKET
ALERT LIGHT LOCATED WHERE
IT CAN BE EASILY SEEN.
FLOAT SWITCH
WIRES FROM
DEHUMIDIFIER
90-1863
PLASTIC
WIRE STAPLE
90-1931
7