1. Foreword 1.1 Introduction Thank you for your chose our electronic pricing scales. Please read this manual first before you use this scale. And please keep this manual for future reference or use. All the information in this manual is same as what we the launched. Our company reserves the right of changing and updating our production in anytime.
1.4 Dimension 1.5 Keyboard distributes and function keys 1. Hotkeys: 2. Function keys:...
Page 5
Functions of keys: Keys Functions Number keys Clear input information; Delete all sale goods. Accumulating sale Print receipt and reports Set to zero point manually Delete the packing and container weight from total weight Save or call out 60 kinds of goods information by these keys Quantity sales Clear one goods information;...
1.6 Accessories Name Quantity Main machine Adaptor Manual USB data line Thermal printing paper Scale pan Packing list Warranty card Cash Drawer Operation Purchase Barcode scanner Operation Purchase...
2. Assemble guide 2.1 Pricing scale components assemble 1. Please put the scale on a stable and level place. Adjust the four screw feet, and make sure the scales on a level situation. (gradienter’s bubble in the center) 2. Connect the various cables as picture shown: 3.
Turn on the power, then the scale will initialize. The display will show 0 after the initialize process, and a buzzer sound. And you can use the scales freely. If the display is not show 0, please press the ZERO key. Note: Please make sure don’t touch the scales pan and there isn’t anything on the scales pan when the scales start the initialize process.
3. Operating Instruction 3.1 Zero Manual operation: if there are no goods on the scale pan, but the display shown is not “0.000”, please press Zero key to make the display shown is “0.000”. Note: if the weight is over 1.2kg (4% of weighting scope), the manual zero operation doesn’t work. Automatic operation: Turn on the scales, less than 3kg, the scale will automatic to zero, if cannot return to zero there will be a warn sound.
3.4 Changing Price Temporary change price: directly input the number of new price when in the sales Permanent change price: input the new price of goods, and press Save key, and then revise the price of the corresponding hot keys ( if change the price of 31-60 hot keys, you should use the shift key to change to corresponding one.
report includes the sales amount of this month. (Operation method in 4.1) 3.7 Change When finish the sales, and need to calculate the change, press the CHANGE key, and input the received money by number keys. The change will be shown on the total price window.
3.11 Standby for saving power When there is nothing on the scale’s pan, and no any operation in 20 seconds, the scale will in the standby for saving power situation, then the weight window’s LED is flashing. Press any key, can let the scales go back the normal situation. Caution: When battery-operated ,when battery is low power will affect the weighing accuracy.
4. Editing Menu 4.1Menu instructions Press[9999][MENU],go to Menu window Keys instructions [MENU] Entry or exit menu Shift typewriting: digits capital letters lower case [SHIFT] [PRINT] Confirm input information Clear input information or back to last menu [BACK Clear one digit or letter SPACE] Display instructions Weight window...
Page 14
1.3print gray [9999][MENU][1][3][x][PRINT][MENU] [x] = 0~9,the more black the x larger 1.4weight unit [9999][MENU][1][4][x][PRINT]MENU] [x] = [1] = kg [2] = 500g [3] = lb 1.5 Edit head [9999][MENU][1][5][x]<input head information>[PRINT][MENU] information [x] = [1] = Edit the first line information; [2] = Edit the second line message;...
Page 15
Period [9999][MENU][3][5] Report <input Start date:eg180101 >[PRINT] <input End date:eg181001 >[PRINT] Clear-out [9999][MENU][3][6] report <input 12345678 >[PRINT] QR code [9999][MENU][4][1] Input content [PRINT][MENU] Receipt [9999][MENU][4][2]][x] [PRINT][MENU] copies X=Figures between 0 and 9 4.3 Lock item [9999][MENU][4][3][x][PRINT]MENU] [x] = [1] = yes; [2] =no;...
Page 16
Minimum [9999][MENU][5][2][x][PRINT]MENU] weight printed [x] = [1] = yes; [2] =no; Paper [9999][MENU][5][3][x][PRINT]MENU] senser [x] = [1] = yes; [2] =no; 5.4.1 [9999][MENU][5][4][1] Label Bar-c Input Bar-code prefix bar-co [PRINT][MENU] prefix 5.4.2 [9999][MENU][5][4][2] Input Plu No. length [PRINT][MENU] length 5.5 Mac ID [9999][MENU][5][5] Input Mac ID(figures between 1 and 9999)...
4.3 PLUS Setting On sales window, press[9999][MENU][2] a.press[C], input PLU NO.,press[PRINT] b.press[C], input PLU name,press[PRINT] c.press[C], input unit price, press[PRINT] d.press[C], input bar-code, press[PRINT],after beep skip to step a for next PLU press[MENU] exit edit PLUS...
5. PC Software Operation 5.1 Install driver software Copy the files in CD to computer, unzip PL2303_Driver (for windows 7_xp_vista).rar or PL2303_Driver (for windows 8) .rar to PC according the PC system.After installation, connect the B type USB cable supplied to PC, Press [My computer]→attribute→Device manager, show as picture: If USB to COM port means installation is right, if yellow !,it’s wrong.
The left number is goods NO.input goods’s price,name,bar-code.(Bar-code must be have and can’t be same for different goods.barcode can be same as goods number ) After edit the goods information,press save as picture to PLUDATA.HEX. Download the goods information to scale: By U-Disk:after step 3,close the PLU EDITOR software,find the ,copy this to U disk root directory,insert U –disk to file...
1)click “Set”download information to scale. 2)close the software,find the file ,copy this to U-disk,and press “SAVE” then OK. 5.4 Immediately upload the day-book report. Inset the U-disk to the USB port, when the scales sale the goods, there will create a file (file name “REG+date”, such as : means December 15th day-book report,) and save in the U-disk.
6. Maintain daily and safety instructions Avoid to put scale in wet or dusty environment. Be careful that AC power cable should not be placed in traffic rout or direct sunlight. Avoid to put the heavier object than defined capacity on the scale, if this happens , message “OL”...
7. Error message & Fault self-inspection If scale can’t work ,please try to solve problem according follow ways by yourself before maintenance. Error No. Reason ERR-01 Sell over 50 items ERR-02 Total Amount over max value ERR-03 No paper ERR-04 Low voltage ERR-05 Memory wrong...
Page 24
putted in U-disk root directory;3.Don’t use system U-disk Power down:Auto power Make sure scale is connected to power off when scale is working adapter while working; change a new power adapter if former one damaged (battery is only charged when scale is power on)...