Technical Data - Bosch Climate Line 5000 Installation Instructions Manual

Hide thumbs Also See for Climate Line 5000:
Table of Contents

Advertisement

Available languages

Available languages

Technical Data

7
Technical Data
Set
Indoor unit
Outdoor unit
Cooling
Rated output
Power input at rated output
Output (min. - max.)
Power input (min. - max.)
Energy efficiency (EER)
Heating
Rated output
Power input at rated output
Output (min. - max.)
Power input (min. - max.)
Energy efficiency (COP)
General
Power supply
Max. power consumption
Max. current consumption
Refrigerant
Refrigerant charge
Design pressure (liquid side/gas side)
Indoor unit
Air flow rate (high/medium/low)
Sound pressure level (high/medium/low/noise reduction)
Permissible ambient temperature (cooling/heating)
Net weight/gross weight
Outdoor unit
Air flow rate
Sound pressure level
Permissible ambient temperature (cooling/heating)
Net weight/gross weight
Table 12
10
CLL5000-Set 22 WE CLL5000-Set 28 WE CLL5000-Set 34 WE
CLL5000 W 22 E
CLL5000 22 E
kW
2.2
kBTU/h
7
W
685
KW
1.0-2.5
W
80-1000
3.21
kW
2.3
kBTU/h
8
W
650
KW
0.7-2.9
W
110-1240
3.61
V / Hz
220-230 / 50
W
2300
A
10.5
R32
g
580
MPa
4.3/1.7
3
m
/h
500/360/300
dB(A)
39/33/24/23
°C
16...32/0...30
kg
8.2/10.4
3
m
/h
1800
dB(A)
56
°C
0...50/–15...24
kg
22.8/24.7
CLL5000 W 28 E
CLL5000 W 34 E
CLL5000 28 E
CLL5000 34 E
2.8
3.4
9
12
867
1049
1.2-3.2
1.3-3.8
100-1250
280-1393
3.21
3.21
3.2
3.5
11
12
893
974
0.9-3.8
1.0-4.0
140-1340
300-1442
3.61
3.61
220-230 / 50
220-230 / 50
2300
2300
10.5
10.5
R32
R32
580
540
4.3/1.7
4.3/1.7
500/360/300
506/375/310
39/33/24/23
39/31/24/23
16...32/0...30
16...32/0...30
8.2/10.4
8.1/10.4
1800
1800
56
56
0...50/–15...24
0...50/–15...24
22.8/24.7
23.7/25.5
Climate Line 5000 – 6721831678 (2021/02)