 Ethernet cable connection
• Connect or remove an Ethernet cable after switching the power of the inverter OFF.
• PORT1 and PORT2 do not need to be distinguished.
• When only one connector is used in star topology, either PORT1 or PORT2 is applicable.
• When using two connectors for line topology and ring topology, an Ethernet cable can be connected to the connectors in any combination. For example,
the cable can be connected between PORT1s or between PORT1 and PORT2.
Connection between
PORT1 and PORT1, PORT2 and PORT2
Connector
Connector
for
for
communication
communication
(PORT1)
(PORT2)
NOTE
• Ethernet is a registered trademark of Fuji Xerox Corporation in Japan.
• For details on CC-Link IE TSN communication, refer to the FR-A8NCG Instruction Manual.
3

BASIC OPERATION

3.1
Operation panel (FR-DU08)
(b)
(c)
(d)
(e)
Connector
Connector
for
for
communication
communication
(PORT1)
(PORT2)
To the next
connector for
communication
(PORT2)
No.
Name
(a)
Setting dial
(b)
MODE key
(c)
SET key
(d)
ESC key
(a)
(e)
PU/EXT key
Connection between
PORT1 and PORT2
Connector
Connector
Connector
for
for
for
communication
communication
communication
(PORT1)
(PORT2)
(PORT2)
The setting dial of the Mitsubishi Electric inverters. Turn the setting dial to change
the setting of frequency or parameter, etc.
Press the setting dial to perform the following operations:
• To display a set frequency in the monitoring mode (The monitor item shown on the
display can be changed by using Pr.992.)
• To display the present setting during calibration
• To display a fault history number in the fault history mode
Switches the operation panel to a different mode.
The easy setting of the inverter operation mode is enabled by pressing this key
simultaneously with [PU/EXT] key.
Every key on the operation panel becomes inoperable by holding this key for 2
seconds. The key inoperable function is invalid when Pr.161="0 (initial setting)".
(Refer to the FR-A800 Instruction Manual (Detailed).)
Confirms each selection.
When this key is pressed during inverter operation, the monitor item changes.
(The monitor item can be changed according to the settings of Pr.52, Pr.774 to
Pr.776.)
Goes back to the previous display.
Holding this key for a longer time changes the display back to the monitor mode.
Switches between the PU operation mode, the PUJOG operation mode, and the
External operation mode.
The easy setting of the inverter operation mode is enabled by pressing this key
simultaneously with [MODE] key.
Also cancels the PU stop warning.
Operation panel (FR-DU08)
Connector
for
communication
(PORT1)
To the next
connector for
communication
(PORT2)
Description
WIRING
9