Lumel ND30PNET User Manual & Quick Start

Lumel ND30PNET User Manual & Quick Start

Meters of network parameters
Hide thumbs Also See for ND30PNET:

Advertisement

Available languages

Available languages

Quick Links

MIeRnIKI pARAMeTRÓW SIeCI
MeTeRS OF neTWORK pARAMeTeRS
ND30
PNET
ND30
BAC
InSTRUKCJA OBSŁUGI - SZYBKI START
pl
USeR'S MAnUAl - QUICK START
en
Zeskanuj mnie
Zeskanuj kod
Scan the code
pełna wersja instrukcji dostępna na
Full version of user's manual available at
www.lumel.com.pl
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ND30PNET and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Lumel ND30PNET

  • Page 1 MIeRnIKI pARAMeTRÓW SIeCI MeTeRS OF neTWORK pARAMeTeRS ND30 PNET ND30 InSTRUKCJA OBSŁUGI - SZYBKI START USeR’S MAnUAl - QUICK START Zeskanuj mnie Zeskanuj kod Scan the code pełna wersja instrukcji dostępna na Full version of user’s manual available at www.lumel.com.pl...
  • Page 2 1. WYMAGANIA PODSTAWOWE, BEZPIECZEÑSTWO U¯YTKOWANIA W zakresie bezpieczeństwa użytkowania odpowiada wymaganiom normy PN-EN 61010-1. Uwagi dotyczące bezpieczeństwa: · Instalacji i podłączeń miernika powinien dokonywać wykwalifikowany personel. Należy wziąć pod uwagę wszystkie dostępne wymogi ochrony. · Przed włączeniem miernika należy sprawdzić poprawność połączeń. ·...
  • Page 3 Rys.2. Mocowanie miernika Wymiary obudowy 96 x 96 x 77 mm, wymiary otworu montażowego Wymiary obudowy 96 x 96 x 77 mm, wymiary otworu montażowego 92,5 x 92,5 mm.Na zewnątrz miernika znajdują się listwy zaciskowe, śrubowe 92,5 x 92,5 mm.Na zewnątrz miernika znajdują się listwy zaciskowe, które umożliwiają...
  • Page 4: Panel Przedni

    (strona poprzednia). Stronę stanowi 8 wielkości wybranych z tablicy 1 (patrz pełna wersja instrukcji obsługi - dostępna na www.lumel.com.pl) i wy- świetlanych na ekranie. Defi niowanie stron opisano w grupie Wyświetlanie. Przyciski miernika w zależności od miejsca obsługi mogą...
  • Page 5 (dotczy tylko ND30PNET) alarmów Transmisja Temperatura Alarm 1, 2 danych RS485 T1, T2 Rys.9. Pasek informacyjny ND30PNET i ND30BAC w wykonaniu z wejściami Pt100 Podłączony Ethernet/Profinet - dot. ND30PNET Podłączony Ethernet/BACnet IP - dot. ND30BAC Komunikacja Błąd kolej- ze sterownikiem PLC ności faz...
  • Page 6: Rozpoczęcie Pracy

    4.2 Rozpoczęcie pracy Po załączeniu zasilania miernik wyświetla logo, nazwę miernika ND30PNET/ ND30BAC, wykonanie, aktualną wersję programu oraz MAC, a następnie przechodzi do trybu pomiarowego, ustawiając się na ostatnio ustawionej stronie. Wyświetlane informacje: np.: ND30PNET v:1.00– typ miernika, nr wersji programu Bootloader v.01.05 nr wersji bootloadera...
  • Page 7 7 KONFIGURACJA PARAMETRÓW MIERNIKA W czasie normalnej pracy wyświetlane są wartości wielkości wg stron zaprogramowanych fabrycznie lub skonfigurowanych przez użytkownika w grupie parametrów Wyświetlanie. wejść menu parametrów należy nacisnąć przycisk Menu miernika podzielono na grupy parametrów: przez ok. 3 sekundy. Parametry –...
  • Page 8 Ustawienia Czas do min. Poziom Wybór stron Kolor stron jasno ci [s] fabryczne stron jasno ci ND30PNET-07 / Instrukcja obsługi / Strona 1 Zielony Minimalny Ustawienia 0000 Czerwony Strona 2 redni ółty Strona 3 Maksymalny Oliwkowy Strona 12 Ustawienia Czas do min.
  • Page 9 * dostępne tylko w mierniku ND30 Rys.12e. Matryca programowania ND30 i ND30 PNET...
  • Page 10: Dane Techniczne

    6. DANE TECHNICZNE Zakresy pomiarowe i dopuszczalne błędy podstawowe Tablica 1 ∑ Wielkość mierzona Zakres pomiarowy Klasa Prąd I: 1/5 A In 1 A ~ 0,002 ..0,100..1,200 A 5 A ~ 0,010 ..0,500.. 6,000 A (PN-EN ...100,00 kA (tr_I≠1) 61557-12) Napięcie U L-N: 57,7 V~ 5,700..11,500 ..70,000 V...
  • Page 11 / Prąd wtórny przekładnika prądowego, tr_U - Przekładnia przekładnika napięciowego = Napięcie pierwotne przekładnika / Napięcie wtórne przekładnika napięciowego, Zalecane jest wykonywanie potwierdzenia metrologicznego miernika w laboratorium LUMEL S.A. nie rzadziej niż co 13 miesięcy. Pobór mocy: - w obwodzie zasilania  6 VA - w obwodzie napięciowym...
  • Page 12 Wejścia binarne separowane (B1, B2): 0 V d.c. – wejście binarne nie- aktywne; 5...24 V d.c. – wejście binarne aktywne Wejścia (T1, T2): 2 x Pt100, 2 – przewodowe, -50 ..+400 °C, błąd pod- stawowy 0,5 % Interfejs szeregowy RS485: Modbus RTU 8N2,8E1,8O1,8N1. Adres 1..247,Prędkość...
  • Page 13 - dopuszczalny współczynnik szczytu : prądu: 2 , napięcia: 2 - zewnętrzne pole magnetyczne:  40...400 A/m d.c.;  3 A/m a.c. 50/60 Hz - przeciążalność krótkotrwała wejścia napięciowe 5 sek. 2 Un wejścia prądowe 1 sek. 50 A - pozycja pracy: dowolna - czas nagrzewania 15 min.
  • Page 14 PNET - tablica 2 ND30 BAC - tablica 3 Tablica 2 Miernik ND30PNET X X X XX X Napięcie wejściowe (fazowe/międzyfazowe) Un: 3 x 57,7/ 100 V, 3x 230/ 400 V 3 x 110/ 190 V, 3 x 400/ 690 V Dodatkowe wyjścia/ wejścia:...
  • Page 15 Tablica 3 Miernik ND30BAC X X Napięcie wejściowe (fazowe/międzyfazowe) Un: 3 x 57,7/ 100 V, 3x 230/ 400 V 3 x 110/ 190 V, 3 x 400/ 690 V Dodatkowe wyjścia/ wejścia: 2 przekaźniki 2 przekaźniki, 1 wyjście analogowe, 2 wejścia PT100 2 przekaźniki, 1 wyjście analogowe, 2 separowane wejścia binarne Interfejs:...
  • Page 16: Basic Requirements And Operational Safety

    1. BASIC REQUIREMENTS AND OPERATIONAL SAFETY In the safety service scope, the meters meet to requirements of the EN 61010 -1 standard. Observations Concerning the Operational Safety: • All operations concerning transport, installation, and commissioning as well as maintenance, must be carried out by qualified, skilled personnel, and national regulations for the prevention of accidents must be observed.
  • Page 17: Meter Description

    Rys.2. Mocowanie miernika Wymiary obudowy 96 x 96 x 77 mm, wymiary otworu montażowego 92,5 Housing overall dimensions 96 x 96 x 77 mm, dimensions of the assembly x 92,5 mm.Na zewnątrz miernika znajdują się listwy zaciskowe, śrubowe hole 92.5 x 92.5 mm. There are screw terminal strips on the outer side które umożliwiają...
  • Page 18: Front Panel

    (previous page). The page consists 8 values selected from the Table 1 (see full user’s manual - avialable at www.lumel.com.pl) and displayed on the display. The page defi nition is described in the Display group. Depending on the location, meter buttons can perform different functions.
  • Page 19 Ethernet/Profinet Czas RS485 Binary inputs Warunki Komunikacja Alarm 1, 2 Alarm 1, 2 alarmów data transmission Wejścia binarne ze sterownikiem Transmisja B1, B2 B1, B2 danych RS485 Fig. 9b. ND30PNET and ND30BAC Information bar - version with binary inputs...
  • Page 20: Starting Work

    Starting work After switching the supply on, the meter displays the ND30PNET or ND30BAC meter name, version, current software version and MAC for the version with Ethernet and then moves to the measurement mode and last saved page. Displayed information: eg.
  • Page 21 To enter the parameters menu press the button for approx. 3 seconds. Buttons allow to select the appropriate mode, to accept press the button To return to a measurement mode use the button ND30-09C User's manual Voltage Voltage Connection Pt100 reist Demand Current Current...
  • Page 22 Selection of Colors of Default Level Time to Time to min. pages pages settings of min. of brightness brightness pages brightness Page 1 Green Minimum [s.] Settings Page 2 Medium 0000 yellow Page 3 Maximum 0000 Olive Page12 Page 1 Field of display1 Field of display2 Field of display8...
  • Page 23 Default Mode Baudrate Address settings reg. 42xx 4800 b/s Modbus 9600 b/s RTU 8N2 19,2 kb/s RTU 8N1 38,4 kb/s RTU 8O1 57,6 kb/s RTU 8N1 115,2 kb/s Default Time Date Password Language settings Settings English 13.47 08/09/2018 **** Polski Deutsch Program Serial...
  • Page 24: Technical Data

    TECHNICAL DATA Measuring ranges and admissible basic errors Table 1 ∑ Measuring value Measuring range Class Current I: 1/5 A In 1 A ~ 0.002 ..0.100..1.200 A 5 A ~ 0.010 ..0.500.. 6.000 A (EN 61557-12) ...100.00 kA (tr_I≠1) Voltage U L-N: 57.7 V~ 5.700..11.500 ..70.000 V 110 V~...
  • Page 25 Frequency f 45,000 ..65,000 .. 100Hz (EN 61557-12) Harmonic distortion factor of voltage 0.0 .. 100.0 % (EN 61557-12) THDU, current THDI Harmonic 0.0 .. 100.0 % amplitudes of voltage U ...U (IEC61000-4-7) current I … I tr_I - Current transformer ratio = Transformer primary current / Current transformer secondary current tr_U - Voltage transformer ratio = Transformer primary voltage / Voltage transformer secondary voltage...
  • Page 26 Harmonics: Harmonic (n) 1..51 Harmonic distortion factor referred to the voltage THD, current THD (n=2..51) 0.0 ..100.0%; FFT analysis (Fast Fourier Transform) Real Time Clock: ±20 ppm, real time clock battery CR2032 Terminals: Cross section 0.05 .. 2.5 mm² Clamping screws M3 Tightening torque 0.5 Nm Protection grade ensured by the housing: from the front IP 65;...
  • Page 27: Ordering Codes

    • maximum phase-to-earth operating voltage: • for supply circuits and relay outputs 300 V • for measurement input 500 V • for circuits RS-485, Ethernet, Profinet (for ND30PNEt), analog outputs, temperature or binary inputs : 50 V • altitude a.s.l. < 2000 m.
  • Page 28 Table 3 Meter ND30BAC X Input voltage (phase/phase-to-phase) Un: 3 x 57.7/ 100 V, 3x 230/ 400 V 3 x 110/ 190 V, 3 x 400/ 690 V Additional outputs /inputs: 2 relays 2 relays, 1 analog output, 2 inputs PT100 2 relays, 1 analog output, 2 binary inputs (galva- nically separated) Interface:...
  • Page 29: Schematy Podłączeń

    +(-) -(+) +(-) -(+) 16 17 22 23 ND30 PNET Ethernet / Profinet Rys 3a. Podłączenia miernika ND30PNET w wykonaniu z wejściami binarnymi Fig.3a. Connections of ND30PNET meter - version with binary inputs / option Opcja RS485 0 .. 20 GNDI...
  • Page 30 GNDI 16 17 22 23 ND30 PNET Ethernet / Profinet Rys.4. Podłączenia miernika Rys 3c. Podłączenia miernika ND30PNET w wykonaniu z wejściami Pt100 Fig.3c. ND30PNET Meter connections - version with PT100 inputs ND30 PNET Opcja RS485 0 .. 20 GNDI...
  • Page 31 ND30-07 Rev.C (Instrukcja obsługi) ND30 Rev.C (Instrukcja obsługi) 2 11 ND30 Rys.5. Pomiar bezpośredni, półpośredni i pośredni w sieci 1- fazowej Rys 4. Pomiar bezpośredni, półpośredni i pośredni w sieci 1- fazowej 2 11 Fig.4. Direct measurement, indirect and semi-indirect in a 1-phase network Pomiar bezpośredni ND30...
  • Page 32 Pomiar półpośredni w sieci 4 - przewodowej Semi-indirect measurement in 4-wire network ND30 Pomiar półpośredni w sieci 4 - przewodowej w sie przew Pomiar pośredni w sieci 4 - przewodowej Indirect measurement in 4-wire network ND30-07 Rev.C (Instrukcja obsługi) Pomiar pośredni ND30 w sieci 4 - przewodowej wyko...
  • Page 33 Pomiar bezśredni w sieci 3 - przewodowej Rys.6. Podłączenia sygnałów wejściowych w sieci trójfazowej 4 – przewodowej Direct measurement in 3-wire network ND30 omiar bezpośredni sieci 3 - rzewodowej Rys.6. Podłączenia sygnałów wejściowych w sieci trójfazowej 4 – przewodowej ND30 miar bezpośredni eci 3 - wodowej...
  • Page 34 Pomiar pośredni z wykorzystaniem 2 przekładników prądowych i 2 lub 3 prze- kładników napięciowych w sieci 3 - przewodowej Indirect measurement using 2 current transformers and 2 or 3 voltage transfor- mers in a 3-wire network ND30-07 Rev.C (Instrukcja obsługi) ND30 Pomiar pośredni z wykorzystaniem 2 przekładników prądowych i 2 lub 3...
  • Page 36 LUMEL S.A. ul. Sulechowska 1, 65-022 Zielona Góra, Poland tel.: +48 68 45 75 100, fax +48 68 45 75 508 www.lumel.com.pl Informacja techniczna: tel.: (68) 45 75 306, 45 75 180, 45 75 260 e-mail: sprzedaz@lumel.com.pl Realizacja zamówień: tel.: (68) 45 75 207, 45 75 209, 45 75 218, 45 75 341 fax.: (68) 32 55 650...