PRODUCT SPECIFICATIONS

Maximum Flow Rate: 1.2 GPM (4.5 LPM) at 60 PSI
ASME A112.18.1/CSA B125
NSF/ANSI/CAN 61
Chrome, brushed nickel or oil-rubbed bronze finish

INSTALLATION INSTRUCTIONS

1. Shut off the water at the supply
valves under the sink or at the
main water supply. Disconnect
the supply lines. Remove the
existing faucet from the sink.
Clean and dry the surface area
where the new faucet will be
mounted.
2. Ensure the gasket (2.1) is in place on
the bottom of the faucet body (A).
Apply a thin bead of silicone sealant
to the underside of the gasket (2.1).
Insert the shanks (2.2) on the faucet
body (A) through the holes in the
sink (2.3). From underneath the sink,
thread the mounting nuts (C) onto
the shanks (2.2) on the faucet body
(A). Check the position of the faucet
and hand tighten until the faucet is
securely mounted. NOTE: It is helpful
to have a second person hold the
faucet in place while tightening
the mounting nuts (C).
3. Push the quick-connector (3.1)
on the end of the spray hose
(3.2) into the quick-connect
coupling (3.3) on the quick-
connect sprayer outlet (3.4).
Give the spray hose (3.2) a tug
to ensure the coupling is securely
connected. If it is necessary to
disconnect the spray hose (3.2)
from the faucet, squeeze the
tabs on the side spray quick-
connect outlet (3.4) and pull
down on the quick-connector
(3.1) on the spray hose (3.2)
to disconnect.
4. After connecting the spray hose
(4.1), attach the weight clip (D)
to the spray hose (4.1) at the
location indicated. To attach the
weight (E), use a screwdriver to
detach one side of the weight
(E) from the other. Then connect
the two pieces of the weight (E)
back to each other around the
spray hose (4.1).
1
2
A
2.1
2.3
C
3
3.4
3.3
3.1
3.3
3.2
4
E
E
D
D
4.1
Ceramic cartridges
Manufactured to include no more than 0.25% weighted average lead
content on wetted surfaces
5.
Attach one end of each of the water
supply lines onto the shanks (5.1)
on the faucet body (A), with hot
water on the left and cold water on
the right. Use 1/2 in. IPS faucet
connections (5.2) or supply line
coupling nuts (5.3) with 3/8 in. OD
ball-nose risers (5.4). NOTE: Do
not reuse existing supply lines.
When installing new water supply
lines, please refer to the supply line
manufacturer's installation
instructions. Tighten the supply line
connections using an adjustable or
basin wrench. Do not overtighten.
6.
To install the pop-up drain
assembly (B), remove the
bottom gasket (6.1) and
mounting nut (6.2) from the
pop-up drain assembly (B).
Push the bottom gasket (6.1)
down onto the top of the
mounting nut (6.2) and twist to
attach together.
2.2
7.
Insert the pop-up drain
assembly (B) into the drain
hole in the sink (7.1). Ensure
the top gasket (7.2) rests
securely between the top of
the sink and the top of the
drain assembly (B).
8.
From underneath the sink,
screw the bottom gasket (8.1)
and mounting nut (8.2) onto the
drain assembly (B) by twisting
until secure against the bottom
of the sink.
NOTE: Remember to reconnect
the drain body to the P-trap
drain before testing the faucet.
2
5
5.1
5.4
5.3
6
B
6.1
6.2
7
7.2
B
7.1
8
B
8.1
8.2
Homewerks.com
5.2

Advertisement

Table of Contents
loading

This manual is also suitable for:

H13l-421-bnH13l-421-orb

Table of Contents