To Test Thermostat
WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS
VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE
THE THERMOSTAT AND VOID YOUR WARRANTY.
CAUTION: D
O NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW
(10°C). T
HIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL
.
INJURY
1. Place the COOL-OFF-HEAT
switch into the COOL position.
2. Press the
button until the temperature setting is at least 3 degrees
below the room temperature. The air conditioning system should
turn on within a few seconds.
NOTE: T
HERE IS A BUILT IN
. A
TION
SECOND ATTEMPT TO TURN ON THE AIR CONDITIONING WILL RESULT IN A
5-
MINUTE DELAY IN COMPRESSOR ACTIVATION
3. Put the COOL-OFF-HEAT switch into
the OFF position. The air conditioning
system should turn off. The fan may
continue to run for a short period of time.
4. Put the COOL-OFF-HEAT switch
into the HEAT position.
5. Press the
button until the temperature setting is at least
3 degrees above room temperature. The heating system should turn
on. The fan may not turn on immediately, depending on the fan delay
built into the furnace.
6. Put the COOL-OFF-HEAT switch
into the OFF position. The heating
system should turn off. Once again,
the fan may have a delay.
7. Put the
AUTO–ON switch
to the ON position. The blower
fan should turn on.
8. Put the
AUTO–ON switch
to the AUTO position. The blower
fan should turn off.
5-
MINUTE DELAY ON BREAK FOR COMPRESSOR PROTEC
.
9
50°F
COOL-OFF-HEAT
-
COOL-OFF-HEAT
COOL-OFF-HEAT
COOL-OFF-HEAT
AUTO - ON
AUTO - ON