Lincoln Electric LN-25 Service Manual page 47

Portable cv/cc semiautomatic wire feeder
Hide thumbs Also See for LN-25:
Table of Contents

Advertisement

F-9
GAS SOLENOID VALVE AND SOLENOID PC BOARD TEST
3. Locate and remove the two solenoid leads from
the solenoid valve (For codes 9812 and below,
remove the two leads from the Solenoid PC
Board). See Figure F.2.
4. Make sure the gas supply for the solenoid is
hooked up, and then apply 12 VDC to the gas
solenoid.
5. If the solenoid activates and allows gas flow,
then the solenoid valve is good.
NOTE: There should not be any gas flow until the
solenoid is activated.
All manuals and user guides at all-guides.com
TROUBLESHOOTING AND REPAIR
(continued)
FIGURE F.2 – SOLENOID LEADS.
SOLENOID LEADS
6. If the solenoid does not activate and allow gas
to flow, then the solenoid is faulty. Replace.
7. The
nor mal
approximately 20 to 27 ohms.
LN-25™
SOLENOID LEADS
solenoid
resistance
F-9
is