PowerPack 2000S Manual for Installation and Operation INPUT AC WARNING! Electric shock hazard, dangerous Voltage range 200-240 V ±10% voltages and currents. Max. current 16 A No user-serviceable parts inside. Frequency 47-63 Hz INPUT DC Before opening the cover, read Max.
All work on the equipment should be done Thank you for purchasing a LORENTZ product. including the following: maintenance, inspection and installation must when it is not being operated and ideally electrically be fully qualified and trained.
3 Specifications 4 Application Table 1: Specifications The LORENTZ PowerPack 2000S allows the pump to If PV is disconnected, a separate timer switch can be powered by an AC power supply from the grid or a be used to control the AC power supply to the generator.
Page 4
DC output of the PowerPack. Voltage Description selection voltage value The PP2000S allows 24/7 operation of the LORENTZ Pos 1. 135 V Mandatory position PS2-1800 / PS2-600 pump systems by connecting the Figure 4: PumpScanner feature settings and 24/7 operation configuration...
PP2000S must be 1 mm² (AWG18) or larger. electrical load to the PV generator other Every solar pump system must be equipped with than the LORENTZ pump controller and a properly sized DC disconnect switch. The switch PowerPack. Connecting the battery...
Operation Troubleshooting 6 Operation 8 Troubleshooting Connect the AC power source and switch on the Before contacting service personnel with PowerPack AFTER it has been connected to the pump troubleshoorting questions, please follow the steps controller. When the controller and the PowerPack outlined in table 4.