4 Setting

Before changing to Setting mode you must change to the M8 thread plug gauge which is delivered as
standard (except for changing the depth mode). A gauge sleeve is not needed in this case!
Press and hold the blue button at the side (button C) for a while (approx. 3 seconds) to change to
Setting mode. This mode can be recognised by the movement pattern of the plug gauge (turning
forwards, backwards) and is the first level.

4.1 Setting level 1 Rotational direction/Torque

Change to this level by pressing the black button (Button B).
The plug gauge now executes a short pattern of movements and then turns slowly in one direction.
You can use this mode to set the rotational direction and torque. This is carried out by using the
adjusting block supplied. There are two levels of holes on this block. These holes only differ in depth
and are not used to calibrate the depth measurement but to select a data set.
To select a data set, three holes must now be tested. The first dictates the rotational direction (right or
left-hand rotation). The second and third holes adjust the required torque. This can be set at nine
different levels.
1st hole
2nd hole
3rd hole
Fig 5: Adjusting block