1. Introduction Note This meter has been designed and tested according to CE Safety Requirements for Electronic Measuring Apparatus, EN 61010-1 EN 61010-2-32 and other safety standards. Follow all warnings to ensure safe operation. Warning Read "Safety Notes"(next page) before using the meter.
2. Safety Notes Read the following safety information carefully before attempting to operate or service the meter. ● Use the meter only as specified in this manual, otherwise the protection provided by the meter may be impaired. ● Always keep hands behind the meter barrier. ●...
● Observe the international electrical symbols listed below. Meter is protected throughout by double insulation or reinforced insulation. Warning ! Risk of electric shock. Caution ! Refer to this manual before using the meter. Alternating current. ▬ … Direct current. Earth (ground).
4. Specifications AC Current Range Resolution Accuracy 40.00A 0.01A ±(2.0%rdg+5dgt) (40~200Hz) 400.0A / 1000A 0.1A / 1A AC Voltage Range Resolution Accuracy ±(1.5%rdg+10mV) 4.000V (40~500Hz) 40.00V 10mV ±(1.5%rdg+5dgt) 400.0V 100mV (40~500Hz) 750V ● Input impedance : 10MΩ DC Voltage Range Resolution Accuracy 4.000V...
5. Instrument layout (10) 2950 CL 3.999 SELECT HOLD 1000 ⑴ ⑹ Transformer Jaws Function Switch ⑵ ⑺ Flashlight Input Terminal ⑶ ⑻ Jaw Trigger SELECT Push Button ⑷ ⑼ Flashlight Button ⑸ ⑽ Data Hold Button Barrier...
Page 10
(1) Transformer Jaws Pick up the conductor within the jaws center. (2) Flashlight For easier viewing in the dark. (3) Jaw Trigger Press to open the jaws. (4) LCD 3¾ digit LCD(4000 counts). (5) Data Hold Button Freeze the reading for all ranges with "HOLD" indicated.
6. Measurement Before proceeding with measurement, read the safety notes. (1) AC current measurement ● Set the function switch to " 1000 " or "40 "range. ● Press the jaw trigger to open the transformer jaws and clamp onto one conductor only. ●...
Page 12
● Connect the test leads to the object to be measured. ● Read the display. Note Reversing the polarity of the test leads displays a negative value. (4) Resistance measurement ● Insert the BLACK lead to the (-)terminal and the RED one to another.
● Connect the 2950 CL red and black test lead, red test lead should connect Diode (+Anode) black test lead should connect Diode (-Cathode). The display will show the reading. 7. Maintenance (1) Battery Replacement: When the low battery warning symbol appears,...