1. Introduction NOTE This meter has been designed and tested According to CE Safety Requirements for Electronic Measuring Apparatus, IEC / EN 61010-1 and other safety standards. Follow all warnings to ensure safe operation. WARNING READ "SAFETY NOTES" (NEXT PAGE) BEFORE USING THE METER.
● Observe the International Electrical Symbols listed below : Meter is protected throughout by double insulation or reinforced insulation. Warning ! Risk of electric shock. Caution ! Refer to this manual before using the meter. AC... Alternating current. DC... Direct current. 3.
● Safety Standard : EN 61010-1 CAT III 600V EN 61326-1 : 2006 IEC 61000-4-2 IEC 61000-4-3 CISPR11 4. Specifications (All at 23°C±5°C, ≤ 80%R.H) ● AC Voltage Range Resolution Accuracy 1 mV 40 V 10 mV ± (1.5% rdg+5dgt) 400 V 100 mV 600 V...
● Accessories : Battery Carrying case Instruction Manual Fixture 6. Instrument Layout (10) (1) Function Selection Switch (6) LED Light (2) LCD Display (7) Red Test Pin (+) (3) Select Button (8) Black Test Lead (-) (4) HOLD Button (9) Cap (5) Back Light Button (10) Fixture...
(1) Function selection switch The function selection switch selects the function. (2) LCD Display 3999 count LCD with LOW BATTERY indication. (3) Select Button For AC/DC function selection. In the resistance + continuity + diode function, press the Select button to select resistance, continuity or diode function.
Page 9
(6) LED Light For penlight function in dark place. (7) Red Test Pin (+) Red Test Pin for positive polarity connection. (8) Black Test Lead (-) Black test lead (-) negative polarity connection. (9) Cap For protection of the tip of the red test pin. (10) The fixture of the black test lead The fixture is used to fix the black test lead for testing.
7. Measurement Before proceeding with measurement , read the safety notes. (1) Voltage measurement Switch to V function for ACV or DCV function. Use the test lead tip to the circuit and read the reading of display directly. If the readings exceed AC 600V(DC 600V), maybe the reading value is wrong and it is dangerous.
(4) Diode Measurement Diode measurement mode shares the same configuration with 4.000V manual voltage measurement mode. If the test circuit is open or the voltage drop between the two ports of the device (diode) under test are larger than 2V, the LCD panel will show "OL".
● Cleaning and Storage WARNING To avoid electrical shock or damage to the meter, Do not get water inside the case. Periodically wipe the case with a damp cloth and detergent. Do not use abrasives or solvents. If the meter is not used for over 60 days, remove the battery for storage.