Function Test & Alignment Procedure; Test Equipment Needed; Service Mode; Osd Reset - Acer X1160Z Service Manual

Acer projector user manual
Hide thumbs Also See for X1160Z:
Table of Contents

Advertisement

Chapter 4
Function Test & Alignment Procedure

4-1 Test Equipment Needed

- IBM PC with SVGA/XGA resolution
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped "Component", "S-Video"
, "Composite" and "HDMI".
- HDTV Source (480P, 720P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327 (Color Video Signal & Pattern Generator)
- After changing parts, check the information below.

4-2 Service Mode

1. Turn on the projector and input the signal
2. Do the following actions sequentially to enter service mode menu
(1) Press "Power> Left>Left>Menu".
(2) Service mode will be shown.
(3) After confirming the configuration, press "Exit" to exit.

4-3 OSD Reset

1. After final QC step, we have to erase all saved change again and resotre the OSD
default setting. The following actions will allow you to erase all end-users' settings and
restore the default setting:
(1) Please enter OSD menu.
(2) To execute "Reset" function.
X1160 Series/X1260 Series/X1160Z Series/X1260K Refresh Confidential
4-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents