Chapter 4
Function Test & Alignment Procedure

4-1 Test Equipment Needed

- IBM PC with 720P resolution (Color Video Signal & Pattern Generator)
- DVD player with Multi-system (NTSC/PAL/SECAM), equipped "Component", "S-Video"
and "Composite"
- HDTV Tuner or Source (480P, 720P, 1080i)
- Minolta CL-100
- Quantum Data 802B or CHROMA2327
- After changing parts, check the information below.
Charge
Version
Parts/
Update
Update
M/B
FW
Color
Wheel
Lamp
Module

4-2 Service Mode

No
Item

Service
Mode
2
Factory
Reset
Confidential
Color Wheel
Index
v
v
v
v
1. Turn on the projector and input the signal.
2. Press these buttons sequentially: Power, Source, Source, Up.
After final QC step, we have to erase all saved change again and
restore the factory defaults. The following actions will allow you to
erase all end-users' settings and restore the original setting:
1. Please enter Menu.
2. Use OSD to reset.
Reset Lamp Use
Time
v
Step
4-
Factory
EDID
Reset
v
v
v