4.6.7 DETAILED PROGRAM EDITING

START -EDIT
PROGRAM
Press and hold SELECT
for about 5 seconds
until 'SL' displays.
Release to view pro-
grammed value
Press until
'SC' displays.
Release to
view value.
Press until
'Rt' displays.
Release to
view value.
Press until
'RC' displays.
Release to
view value.
Press until
'SP' displays.
Release to
view value.
Press until
'Ht' displays.
Release to
view value.
continued on next page ...
Notes and Guidelines:
Programming Mode Locks
To view or edit the sequences, the KEY
Adjust value
LOCK must be unlocked and the software
UP / DOWN
lock (toggled by pressing SELECT + UP
simultaneously) must also be unlocked
(Un). If the lock is on when you attempt to
enter programming an LC will be displayed.
Adjust value
UP / DOWN
(Rt) Batch Reset Time
At batch completion, the scredriver will not
operate fot the length of the batch reset
time setting.
(RC) Slow Start Time
Adjust value
UP / DOWN
The slow start time must be less than the
time required to install the screw. The tool
must switch to full speed before the clutch
activates for shut-off.
(SP) Slow Start Speed
Adjust value
UP / DOWN
Slow start speed is adjustable in steps from
lowest (L1 ~ 30% of full spd) to highest (L9
~ 85% of full spd). L0 equals 100% of run
speed or slow start off.
(Ht) High Time and (Lt) Low Time
Adjust value
UP / DOWN
The Ht and Lt settings establish a time
window for OK/NG evaluation of a fastener
rundown. Low Time (Lt) must be set to a
value lower than High Time (Ht) during
programming or an error (Er) will occur.
Adjust value
Ht value must be > Lt.
UP / DOWN