9. Do not cover the controller or stack any objects on top of or near the controller. Ensure that adequate
clearance and ventilation is provided around the perimeter of the controller.
10. Specific models of 035/E/A / CESL8 series controller are designed for use with 035/E/A series
screwdrivers as specified on the following pages. Use of controller (or screwdriver) with any other
screwdriver (or controller) may result in malfunction, damage, or injury.
11. In the event that the controller is overloaded beyond the maximum current rating, an internal fuse will
disrupt power. Should the controller stop functioning, or exhibit abnormal or intermittent operation,
please discontinue use immediately and send the controller to an authorized service centre for
troubleshooting and repair.
12. Excessive duty cycle will cause the tool and/or controller to overheat. If this occurs, discontinue use
until cooled down and reduce cycle rate. As a general rule, do not exceed 10-15 screws/minute, one 8
hour shift per day.
13. The 035/E/A / CESL8 series screwdrivers incorporate a protection circuit which stops the electric
screwdriver if the tool is switched from forward to reverse while running. Should this happen, the
operator must release the tool trigger and restart the fastening cycle.
14. Power the controller off and wait for 3 seconds before connecting/disconnecting the screwdriver tool
cable to/from the controller.
15. Turn the main power switch off when the controller is not being used. Unplug the controller if it is not
being used on a regular basis.
16. Do not attempt to disassemble or repair the screwdriver or controller. Repairs should only be per-
formed by qualified technicians properly trained in the safe operation, troubleshooting, and repair of
these devices. Please consult Bossard for the location of the nearest service depot.
17. Use only the factory specified Delta Regis brand replacement parts and accessories with these tools
and controllers.
18. Any damage to the tool and/or controller resulting from misuse, abuse, or failure to follow these
guidelines will void the limited warranty period.
Grounding – This controller (and AC power cord) is equipped with a 3-prong electrical
receptacle/plug with ground pin. The controller must be connected to a properly grounded AC elec-
trical outlet. Do not attempt to use this controller without a properly functioning ground connection.
Never connect a live circuit to the ground pin or internal yellow-green ground wire.

4.2 SPECIFICATIONS

Model Number
Input
Output
Speeds
Use exclusively with screwdriver models
Slow Start Function
Slow Start Time Adjustment
Slow Start Speed Adjustment
035/E32V / BECT832N-SSO;
035/E40V / BECT940-SSO
100-240V AC, 50/60Hz, ~6.3A
40 / 32 / 24 VDC,
60W 035/E32V / BECT 832N-SSO
360W 035/E40V / BECT940-SSO
Hi / Lo (switch selectable)
035/E/A 32VDC / 40VDC / CESL8 series screwdrivers
Selectable ON / OFF
0 – 9.9 seconds
~ 30 – 100% of rated speed