Download Print this page

Sharp LC-60LE831U Service Manual page 66

Hide thumbs Also See for LC-60LE831U:

Advertisement

LC-40/46/52/60LE835U/830U/832U/LC-60LE831U
Table 1. Concrete flashing pattern
Item
Inverter/Lamp system failure
Power PWB
failure
(Power failure, etc.)
Main PWB
failure
(Communication
failure, etc.)
Others
VerUP executing
VerUP succeeded
VerUP failed
ROM data failure
*2: They depend on the system. Power supply error is defined from product to product.
*3: For details, refer to ERROR STANDBY CAUSE on the adjustment process screen.
*4: If the boot section is abnormal, there is no flashing (flashing impossible).
3. New method
Center icon
400ms
400ms
Flashing during Verup
Center icon
500ms
500ms
Flashing when completing Verup
Center icon
1000ms
Detail display
Slow flashing
Flashes once
Flashes twice
Flashes 3 times
Flashes 4 times
Flashes smoothly
Flashes in a staircase pattern
None
None
1600ms
300ms
100ms
1000ms
1000ms
1000ms
Fast flashing
Flashes once
Lamp error
Flash once
Power supply error 2 (*2) AC_DET error
Flash twice
Power supply error 2 (*2) UR+13V error
Flash 3 times
Power supply error 2 (*2) D+3.3V error
Flash 5 times
Panel power supply error
Flashes once
Initial communication error
Flashes twice
Start-up confirmation communication error
Flashes 3 times
Regular communication error
Flashes 5 times
Other communication error
Flashes once
Temperature error
Flashes twice
Sync error
Flashes 3 times
Notification from the main microcomputer (*3)
None
Version upgrading
None
Version upgrade succeeded
Flashes continuously
Version upgrade failed
Flashes continuously
Start-up after failing version upgrade (*4)
1600ms
6 – 2
Cause

Advertisement

loading