4 Unit installation
4.2.2
To lower the switch box of the indoor unit
and remove the top cover
During the installation, you will need access to the inside of the
indoor unit. To have easier front access, lower the switch box of the
unit as follows:
Prerequisite: The user interface panel has been removed.
1 Loosen the screws.
2 Lift up the switch box.
3 Lower the switch box.
Installation manual
16
4.2.3
4.3
4.3.1
4.3.2
Spillover water from the water storage tank as well as water
collecting in the drain pan must be drained. You must connect the
drain hoses to an appropriate drain according to the applicable
legislation.
4 If necessary, remove the top cover. This is necessary in the
following cases:
▪ Connecting water piping
▪ Connecting BIV or DB-kit
▪ Connecting backup heater

To close the indoor unit

1 Close the cover of the switch box.
2 Reinstall the top cover.
3 Put the switch box back into place.
4 Reinstall the user interface panel.
NOTICE
When closing the indoor unit, make sure that the tightening
torque does NOT exceed 4.1 N•m.

Mounting the indoor unit

To install the indoor unit

1 Lift the indoor unit from the pallet and place it on the floor. Also
see
"3.1.2 To handle the indoor
2 Connect the drain hose to the drain. See
drain" [ 4  16].
drain hose to the
3 Slide the indoor unit into position.
NOTICE
Level. Make sure the unit is level.

To connect the drain hose to the drain

1 Open the screw plug.
unit" [ 4  7].
"4.3.2 To connect the