NOTICE Metal Assembly Screwdrivers are designed for installing threaded fasteners in light industrial and appliance manufacturing applications. KILEWS is not responsible for customer modification of tools for applications on which KILEWS was not consulted. WARNING Important safety information enclosed.
Important Safety Instructions WARNING! Read all instructions Failure to follow all instructions listed below may result in electric shock fire and/or serious injure. The term “power tool” in all of the warning listed below refer to your mains operated (corded) power tool or battery operated (cordless) power tool.
Page 4
4) Power tool Use and Care a) Do not force the power tool. Use the correct power tool for your application. The correct power tool will do the job better and safer at the rate for which it was designed. b) Do not use power tool if switch does not turn it on or off.
4. Do not near oil, chemical materials or heated objects, also please be alert not to scratch the power cord by sharp object. 5. This type of Controller can only be applied to Kilews Electric Screwdriver with Counter. Do not use Electric Screwdriver Controller on other types of machinery.
Applicable Electric Screwdrivers SKD-BC517LF;SKD-BC517PF Accessories Power cord*1 ※SKP-BC32HL-100N must be used with SIX PIN screwdrivers , so please confirm the screwdriver’s type is SKD-BC series and the connector is SIX PIN when using. Step of the screwdriver confirmation:: “SKD-BC” type.
Control panel specifications Parts Name Parts Name LED Indicator System Build-in Reset Key HI / LO Speed Switch POWER/CLEAR Key Key setting lock Functional Selection / Confirm Key BC 6Pin Connector Buzzer hole WORK Light Power point OK Light POWER SWITCH I/O Inserting Hole *...
Functions of Keys on Panel: Description of function. Remarks POWER: Power Switch To press for Eight seconds, the system will be shut down and LED Display and WORK indicator light will be shut off. To return counting function under shutting down counter condition, push three seconds to open the counter.
I/O Inserting Hole: Name In/Out Content wave pattern of signals Remark Device built-in output voltage DC12V DC12V Output one signal Auto start If operator needs to Output after finishing one input voltage, please do not screwing job. exceed DC 12V/ 10mA Output one signal Auto start If operator needs to when having an...
SW4: Switching Mode: Select ON means the external SENSOR need to have two signals been sent to SKP-BC32HL-100N which stands for the fastener on operational process need to go through the sensor on machine table to identify the fastener has been removed from working table, and new fastener goes through another SENSOR for confirming the new fastener that has reached the working table.
Page 11
SW5: Auto-Learning Mode: The Counter counts screws number with the judging value OK & NG which is set up by Ht and Lt, this Auto-Learning Mode is completely using Electric Screwdriver to fasten screws practically, memorize the screwing time from beginning to complete fastening automatically, user can only change this switch to ON, then system will ask how many screws (SC) of the fastening position been required? If need auto response time setting (At) or if need to use the Slow-Start setting (Rc)? SW6 :...
System setting ※Push three seconds to enter the selection SL====SC====At====RC====SP====Ht====Lt====LL <Confirm> Set up Manufactur Function Name Time and Description Buzz Time/ Light er Set-Up Value Value Screw List 01~05 Counting number / count-down only 01~99 Automatic zero time / Signal output time 0.1~9.9 Slow start time 0.1~9.9...
Page 13
9、To press SELECT, the screen will show push POWER key , adjust decimals 00. push UP/DOWN to increase or decrease number, the maximum can set up 9.90. LL: No times confirmed within set-up time after fastening. “02.” means 0.02 10、To press SELECT to confirm.
Simulated Learning 1、 The switch mode SW5 change into ON. ※When SW5 change to ON, it will force to enter simulated learning procedure, any function will not work. 2、 When it changes to ON, LED will flash. The user can set whether or not counting screws, starting slow-start.
Page 15
CAUTION 1. The use of other than genuine KILEWS replacement parts may Result in decreased tool performance and increased maintenance, and may invalidate all warranties. 2. All repairs and maintenance of this tool and its word must be performed by an authorized service center.
自動模擬學習設定步驟 1、 將模式選擇開關 SW5 切換 ON ※將 SW5 切至 ON 時,將強制進入自動模擬學習設定程序,任何功能將不起作用。 2、 切換 ON 時,LED 會閃爍讓使用者設定是否要計數幾顆螺絲、是否需要用到緩啟動,使用者必須先 確定這些必要條件才可以進行自動學習。 ------------------ ------------------ ------------------ ---------------- ---------CHECK 3、 設定完成後,LED 會顯示 0.0,使用者可以測試鎖螺絲動作,當起子啟動時,LED 會跟著計數,當 起子剎車停止動作時,就是螺絲鎖附完成的時間,使用者可以進行多次測試,直到滿意為止,使用 者可以將 DIP SW5 開關切至 OFF 狀態,如此系統將自動設定 Lt/Ht 的時間。 4、 若使用者認為數值尚不理想,再將 DIP SW5 切至 OFF 狀態時,可按住 SELECT 7 秒以上,進去選單 畫面進行修改。...
Page 27
SKP-BC32HL-100N(CE) NO PARTS NO PARTS NAME-E PARTS NAME-C Q'ty NO PARTS NO PARTS NAME-E PARTS NAME-C Q'ty AA50002 America Plug 美插電源線 19 P11039-3 Housing-Underside 外殼下蓋 AA50002-1 Australia Plug 澳插電源線 20 CH20504-0 Screw 3*5 螺絲 3*5 AA50002-2 Europe Plug 歐插電源線 21 CH20110 Rubber Shim 腳墊...
Need help?
Do you have a question about the SKP-BC32HL-100N and is the answer not in the manual?