Download Print this page

teko Astra-3221 User Manual page 2

Wireless panic button

Advertisement

5 OPERATION MODES
Attention! Setting operation mode of the detec-
tor, as well as LED indication of notifications are
possible within no more than 10 minutes after
battery insertion!
5.1 RF supervision/ No RF supervision
Panic button supports two operation modes:
- With RF supervision (when using the panic
button as a stationary device),
- Without RF supervision (when using the
panic button as a mobile (wearable) device).
Sequencing:
1) Remove the base of the detector (see p.6)
2) Activate battery by pulling out the insulator
3) By the LED indication check the mode:
- 1-time flash – with RF supervision,
- 2-time flash – without RF supervision.
4) To change the mode, wait for 10 sec., press
the panic button and hold it for at least 10 sec.
until the LED flashes, 1-time or 2-time, depend-
ing on the set mode.
5.2 Radio mode selection
The radio mode of the detector is configured by
closing the metallized contacts on the PCB.
Sequencing:
1) If after activating the
battery more than 10
minutes have passed:
reset the battery, wait at
least 10 sec.
2) Close the metallized
Rmod contact until the
indication appears (at
least 10 sec).
3) After turning on the LED, determine the set
radio mode:
- 1-time flash – mode 1,
- 2-time flash – mode 2 (compatible with Secu-
rity Hub).
4) Close the metalized Lit contact until the LED
indication appears (not less than 10 sec).
5) After turning on the LED, determine the set
mode:
- 1-time flash – frequency mode 1 (compatible
with Security Hub),
- 3-time flash – frequency mode 3.
When changing modes on a registered de-
tector it is necessary to re-register the de-
tector!
6 ADDING PROCEDURE
1) De-assemble the panic button.
2) Select mode with or without RF supervision
(p. 5.1) if it is necessary (no need for Security
Hub).
3) Set radio mode and frequency mode (p. 5.2)
if it is necessary (no need for Security hub).
4) Start registration on the Security Hub mobile
app. Registration starts for 45-60 sec.
5) Activate or re-activate the battery.
6) Check the adding in the Security Hub mobile
App.
7) In case of successful adding activate the
second battery and assemble the panic button.
7 INSTALLATION PROCEDURE
 As a stationary device with RF supervi-
sion:
- remove the base;
- remove the PCB;
- fix the base of the detector in the chosen
place;
- install the cover with the PCB fixed on it into
the base.
 As a mobile device without RF supervi-
sion: attach to clothes with a clip or use a cord
(cord is supplied separately).
8 WARRANTY
The operation warranty period is 1 year from the
date of operation start, but no longer than 1 year
6 months from the date of manufacturing
to the requirements of User guide.
subject

Advertisement

loading