IEC 61000-4-8
IEC 61000-4-29
IEC 61000-4-11
IEC 61000-4-12
IEC 61000-4-16
IEC 61000-4-17
IEC 60255-5
IEEE 1613 (C37.90.x) EMC Immunity Type Tests
Note
The RUGGEDCOM RS400 meets Class 2 requirements for an all-fiber configuration
and Class 1 requirements for copper ports.
Dielectric Strength
RUGGEDCOM RS400
Installation Manual, 01/2021, C79000-G8976-1016-11
Test
Magnetic Field
Voltage Dips
and Interrupts
Damped
Oscillatory
Mains Frequency
Voltage
Ripple on DC
Power Supply
Dielectric
Strength
H.V. Impulse
Description
ESD
Enclosure Contact
Radiated RFI
Enclosure Ports
Fast Transient
DC Power Ports
AC Power Ports
Earth Ground Ports
Oscillatory
DC Power Ports
AC Power Ports
DC Power Ports
6.2 EMC and Environmental Type Tests
Description
Enclosure Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
DC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Signal Ports
DC Power Ports
AC Power Ports
Enclosure Air
Signal Ports
Signal Ports
1 kV Common and Differential Mode at 1 MHz
1 kV Common and Differential Mode at 1 MHz
Signal Ports
Test Levels
40 A/m continuous,
1000 A/m for 1 s
30% for 0.1 s, 100% for 0.05 s
30% for 1 period,
60% for 250 periods
100% for 5 periods,
2
100% for 50 periods
2.5 kV common, 1 kV
differential mode at 1 MHz
2.5 kV common, 1 kV
differential mode at 1 MHz
2.5 kV common, 1 kV
differential mode at 1 MHz
30 V Continuous, 300 V for 1 s
30 V Continuous, 300 V for 1 s
10%
2 kVac (Fail-Safe Relay Output)
1.5 kVDC
2 kVAC
5 kV (Fail-Safe Relay output)
5 kV
5 kV
Test Levels
±8 kV
±15 kV
35 V/m
±4 kV at 2.5 kHz
±4 kV
±4 kV
±4 kV
2.5 kV Common Mode at 1 MHz
2 kVAC
1.5 kVDC
Certification
Severity
Levels
 
 
 
 
3
3
3
4
4
3
 
 
 
 
 
 
37