Note: To prevent damage to the device due to static buildup, the device should be properly
grounded. The power supplies Zaber provides for X-Series devices are non-isolated and thus
ground the device chassis to Earth via the negative terminal of the power supply. If for any reason
you are using an isolated power supply, please ensure your device is grounded by connecting the
negative terminal of the power connector to AC Earth.
RS-232 Communications
Default Settings
Baud rate: 115200
Protocol: Zaber ASCII
Specifications
Supported Protocols: Zaber ASCII, Zaber Binary
Supported baud rates: 9600, 19200, 38400, 57600, 115200
Bits: 8
Parity: None
Stop Bits: 1
Flow Control: None
Indicators
Green
- Power
On: Controller is operational.
Blinking twice per second: The power supply voltage or controller temperature is out of
range.
Fading in and out slowly: The device is parked. See the
Red
- System Error
On/blinking: An error has occurred. Please contact
Yellow
- Communication/Busy
1
24 - 48 V
GND (Note: Zaber's power supplies
2
ground this pin to AC Earth)
Pin
Previous
1
Power
2
Ground
3
Receive
4
Transmit