7. Source Calibration (CVBS only support AV3 port used)
(1) Set the signal generator to CVBS, Color bar pattern (level: 0.7V, color order from left side: white,
yellow, cyan, green, magenta, red, bule, black, width ratio: 12.5% for each color)
(2) Entering into factory Mode:Press up or down key of remote control to select
"AV CVBS Calibration", Press 「OK」 key to start adjusting..
HX42CG V1.00
WARM(6500K)
NORMAL(9300K)
COOL(15000K)
Shipping Mode
0 0 0 0 0 2
-> Source calibration performed automatically.
L37X01A / L42X01A
Factory Menu
Aug.2007 10:41:46
NV CLEAR
Full Power
AV CVBS Calibration
Reset Default
TimerClear
Aspect Ratio
HOUR
50
MIN
16