5.Adjustment

5.1 Color Temperature Adjustment Procedure
1. Preparation
1. Set the signal generator (ASTRO VG859A or equivalent) to RGB, 1024*768, 60HZ, Level:0.7V, all
white pattern..
2. Turn on the set and select RGB source,perform pre-heat run more than 30 min. with Full white
pattern.
3. Prepare Minolta CA210,and calibration before adjustment.
4. Press 「Menu」key , Press 「ok」 to select [Picture] [Reset] 「Reset」 「ok」.
Picture
Picture Mode
Contrast
Brightness
Color
Sharpness
Tint
Color Temperature
Back Light
Reset
Select
Set
OK
5. Press [Menu] key exit OSD.
2.
Entering into factory Mode:
In VGA mode, press "Red" key, next press "Green" key, next press "Return" key in remote control to
enter into factory mode.
Red
L37X01A / L42X01A
Dynmaic
75
40
80
11
1
Cool
High
Reset
Return
Green
Return key
Factory Menu
HX42CG V1.00
WARM(6500K)
NORMAL(9300K)
COOL(15000K)
TimerClear
Shipping Mode
0 0 0 0 0 5
HOUR
11
Aug.2007 10:41:46
NV CLEAR
Full Power
SourceCalibration
Reset Default
Aspect Ratio
58
MIN