If used for other or debris — do not use your hands. purposes, JET disclaims any real or implied Do not use this air filtration unit with a warranty and holds itself harmless from any damaged cord or plug.
Page 3
WARNING: Some dust, fumes and gases created by power sanding, sawing, grinding, drilling, welding and other construction activities contain chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. Some examples of these chemicals are: •...
Whatever accepted methods are used, always make personal safety a priority. If there are questions or comments, please contact your local supplier or JET. JET can also be reached at our web site: www.jettools.com.
4.0 Features • Two-filter system with air diffuser disperses outgoing air into a broader pattern • Disposable electrostatic outer filter attracts more dust particles than standard filters • Inner pocket filter is removable for easy cleaning • Can be either bench-top or ceiling mounted o Four eye bolts provided for ceiling mount •...
5.0 Specifications Table 1 Model No. AFS-1000C Stock No. 713000 SPECIFICATION Motor: Motor type BLDC (Brushless Direct Current Motor) Horsepower 1/3HP Phase Electrical: Voltage 120V input, single phase only Frequency 60Hz Listed FLA (full load amps) 3.8 A Motor speed range...
Page 8
= not applicable The specifications in this manual were current at time of publication, but because of our policy of continuous improvement, JET reserves the right to change specifications at any time and without prior notice, without incurring obligations.
6.4 Installation Read and understand the 6.4.1 Overhead (ceiling) entire contents of this manual before attempting assembly or operation. Failure to comply may cause serious injury. Overhead structure (often ceilings) must be capable of supporting the 6.0 Setup weight of the air filtration unit and absorbing any vibrations arising from the unit.
Failure to comply may cause serious injury. The AFS-1000C Air Filtration System is prewired for single phase, 120V power. It is provided with a plug designed for use on a circuit with a grounded outlet Figure 7-1 that looks like the one pictured in Figure 7-1.
When the Power switch (Fig. 8-1, A) is first turned 8.0 Controls Functions ON, power is supplied to the electronics and the AFS unit is in the STANDBY state. All DISPLAYs 8.1 Control Panel Buttons are off. Each press of the ON/OFF button (Fig. 8-1 and 8-2, B) cycles the AFS unit between STANDBY and ON.
FAN SPEED ADJUSTMENT (control In AUTO mode, the integrated sensor detects the air quality and adjusts the fan speed accordingly. panel or remote) Thereby reducing energy consumption when air The SPEED Buttons (Fig. 8-1 and 8-2) on the quality is good and increasing the fan speed when controls and the remote perform the exact same dust is present.
• Replacement Filters: Spray the soap onto the entire filter until fully covered. NOTE: JET brand filters are recommended for best • performance. Allow the soap to soak 1 to 2 minutes on the filter but do not allow the soap to dry. This will 708731 ..
• DO NOT press the ON/OFF button. Allow all excess water to drain off the filter. While the filter does not need to be absolutely Press and hold the SPEED – (minus) and dry, do not return to service if water is dripping SPEED + (plus) buttons on the control panel at or droplets are still visible.
Power cord damaged Replace power cord. Control button or PCBA malfunction Contact JET customer service. Loose frame, parts, or fasteners Inspect and tighten as needed. Clean impeller (do not use solvents). Impeller imbalance Excessive vibration If imbalance still occurs, replace impeller.
12.0 Replacement Parts Replacement parts are listed on the following pages. To order parts or reach our service department, call 1-800- 274-6848 Monday through Friday, 8:00 a.m. to 5:00 p.m. CST. Having the Model Number and Serial Number of your machine available when you call will allow us to serve you quickly and accurately. 12.1.1 AFS Unit –...
12.3.1 Remote Control Assembly – Exploded View 12.3.2 Remote Control Assembly – Parts List Index No Part No Description Size 20 ....AFS1000C-RCA ..Remote Control Assembly ................1 20-1 ... AFS1000C-RC1 ..Remote label....................1 20-2 ... AFS1000C-RC2 ..Remote front case ..................1 20-3 ...
JET sells through distributors only. The specifications listed in JET printed materials and on official JET website are given as general information and are not binding. JET reserves the right to effect at any time, without prior notice, those alterations to parts, fittings, and accessory equipment which they may deem necessary for any reason ®...