Zanussi ZCG61281XA User Manual page 10

Table of Contents

Advertisement

ADJUSTING THE MINIMUM GAS LEVEL ON
THE HOB BURNER
1. Disconnect the appliance from the electricity.
2. Remove the knob for the hob. If there is no
access to the bypass screw dismount the
control panel before adjustment start.
3. With a thin and flat screwdriver adjust the
bypass screw A.
The model determines the position of the
bypass screw A.
A
Changing from natural gas to liquid gas
1. Fully tighten the bypass screw.
2. Put the knob back.
Changing from liquid gas to natural gas
1. Unscrew approximately one turn the bypass
screw position A.
2. Put the knob for the hob back.
3. Connect the appliance to the electricity.
WARNING! Put the mains plug
into the mains socket only if all
parts are back into their initial
position. There is a risk of injury.
4. Light the burner.
Refer to "Hob - Daily use" chapter.
5. Turn the knob for the hob to the minimum
position.
6. Remove the knob for the hob again.
7. Screw on slowly the bypass screw till the flame
becomes minimum and stable.
8. Put the knob for the hob back on.
OVEN INJECTOR REPLACEMENT
1. Remove the bottom plate of the oven cavity A
to get access to the oven burner B.
10
A
B
A
2. Release the screw C, which keep the burner in
position.
C
3. Carefully move the burner off the injector
support D.
E
4. Slowly move it to the left side. Make sure that
the burner bush stays on the burner
mouthpiece. Do not apply force to the wire of
the spark plug connector F and to the
thermocouple conductor E.
D
F

Advertisement