Haier HW120-B14686 Series User Manual page 24

Table of Contents

Advertisement

Available languages

Available languages

9-Troubleshooting
9.2 Troubleshooting with display code
Problem
Cause
E1
• Drainage error, water is not fully drained
within 6 minutes.
E2
• Lock - error.
F3
• Temperature sensor - error.
E4
• Water level not reached after 12 minutes.
• Drain hose is self-syphoning.
F4
• Heating error.
F7
• Motor - error.
E8
• Water protective level - error.
FA
• Water level sensor error.
FC0
• Abnormal communication error.
FC1 or
FC2
UNB
• Unbalanced load - error.
H
• Temperature in the drum is higher
than 80°C.
Fb *
• Water overflow
WARNING!
* Code Fb: Water-overflow protection is placed on deepest part of appliance. In case
of leackage all functions will be shut down automatically except drain pump which will be
activated for safety reasons.
24
.
Solution
• Clean pump filter.
• Check drain hose installation.
• Shut the door properly.
• Contact the After sales service.
• Make sure that tap is fully opened and water
pressure is normal.
• Check drain hose installation.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Contact the After sales service.
• Check and balance laundry load in the drum.
Reduce the load.
• Will release automatically if temperature
is less than 80°C.
• Close tap immediately. Contact the After
sales service.
GB