4. Troubleshooting
Error type
Error mode
1. Check the wire connections for the Fan Motor.
2. Check the resistance of the Fan Motor coil.
(Remove the connector before measuring.)
Normal: Approx. 150 Ω
➢
3. Check the operation of the Fan Motor Relay
Dry error
None
: Check the operating voltage between the white wire of the C1
connector and the sky wire of the CN14 connector.
Normal: 120V (while operating)
➢
New PBA
3-1.Check the operation of the Fan Motor Relay
: Check the operating voltage between the white wire of the C101
connector and the sky wire of the CN201 connector.
Normal: 120V (while operating)
➢
4. Check the operation of the dispenser.
If rinse aids are not dispensed, a dry error may occur.
➢
Because the dishes are heated and heat dried during the
➢
last drying cycle, the dried state of plastic dishes may not be
optimal.
4-14
All manuals and user guides at all-guides.com
Checking Method
Corrective actions
- Reconnect the Fan Motor connectors.
- Faulty: Replace the Fan Motor assy.
- Faulty: Replace the Main PBA assy.
- See "Detergent is not dispensed"
New PBA