8. Crank engine over slightly with starter motor to
purge any water trapped in seawater pickup
pump. DO NOT ALLOW ENGINE TO START.
9. After cooling system has been drained complete-
ly, coat threads of drain plugs with Quicksilver
Perfect Seal. Install all drain plugs and tighten se-
curely. Reconnect all hoses and tighten all hose
clamps securely.
IMPORTANT: MerCruiser recommends that pro-
pylene glycol antifreeze (nontoxic and biode-
gradable, which makes it friendly to lakes and riv-
ers) be used in sea-water section of the cooling
system for cold weather or extended storage.
Make sure that the propylene glycol antifreeze
contains a rust inhibitor and is recommended for
use in marine engines. Be certain to follow the
propylene glycol manufacturer's recommenda-
tions.
Index
1B-28 - MAINTENANCE
10. For additional assurance against freezing and
rust, remove the thermostat cover and thermo-
stat. Fill the engine seawater cooling system with
a mixture of antifreeze and tap water mixed to
manufacturer's recommendation to protect en-
gine to the lowest temperature to which it will be
exposed during cold weather or extended stor-
age. Using a new gasket, reinstall thermostat and
cover. Tighten cover bolts to 30 lb. ft. (41 N·m).
NOTE: Hoses shown removed only to indicate flow.
Do not remove hoses.
a
b
c
f
f
c
a - Cover
b - Gasket
c - Spacer
d - Thermostat
e - O-Ring
f - Housing
g - Fill Here
d
e
g
72589
e
d
g
90-823224--2 796