3-11.
QUICK FILTER
(CONT.)
PURGE VALVE HANDLE
Cook Position (open)
July 2014
9.
Display shows "CLOSE RETURN VALVE" followed by
"CONFIRM". Allow oil to bubble for 10 to 15 seconds and
then close the yellow return valve handle. Press
and the control returns to normal operation.
NOTE: Purge valves are available on select units for solid
shortening. Perform step 10 if purge valve is available, otherwise
continue to step 3-12.
10.
Display shows "OPEN BLACK PURGE VALVE"
followed by "CONFIRM".
NOTE: This prompt only displays if the unit is
enabled for Solid Shortening in the settings. Liquid
shortening is the preferred oil.
IMPORTANT: Leave purge valve in closed position if more vats
need filtered. Press
(closed) position repeat above steps.
Once all vats have been filtered, open purge valve, press
button.
To help ensure the vat fills completely, make sure filter pan is cleaned at least
daily, filter pad is changed, and that "O" rings on the filter pan are in good
condition.
21
button and leave purge handle in the filter
button

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kve-072Kve-073Kve-074

Table of Contents