Functional overview
Ambient conditions
Environment class 3K2
Environment class 2K2
Temperature
Operation (3K2)
Transport (2K2)
Humidity
Condensation during operation must be avoided!
Noise level
The acoustic noise values are depending on the system configuration.
Sound power level L
(ISO 9296)
Sound pressure level at
adjacent workstation
L
(ISO 9296)
pAm
26
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
5°C ... 40°C (with ATD 40°C)
5°C ... 45°C (with ATD 45°C)
10°C ... 35°C (without ATD)
-25°C ... 60°C
10% ... 85% (non condensing)
min. configuration
1x PSU 1x CPU
< 5.1 B (standby)
WAd
< 6.2 B (operation)
< 34 dB(A) (standby)
< 44 dB(A) (operation)
Operating Manual
max. configuration
2x PSU 2x CPU
< 5.3 B (standby)
< 7.7 B (operation)
< 36 db(A) (standby)
< 60 db(A) (operation)