TROUBLESHOOTING
None of the LEDs
on the QNET
Mechatronic
Actuators
board are lit.
On the QNET
Mechatronic
Actuators, the
ELVIS +5V LED is
bright green but
the External +24V
LED is not lit.
The External
+24V LED is
bright green but
the ELVIS +5V
LED is not lit.
STILL NEED HELP?
Register your QNET board at https://www.qnetregistration.com to recieve regular product updates.
Expand your lab using other QNETs for NI ELVIS
• QNET DC Motor
• QNET Rotary Pendulum
• QNET VTOL
• QNET HVAC
• QNET Physics and Dynamics (NEW for 2105)
• QNET Mechatronic Sensors
• QNET Myoelectric
LEARN MORE
©2015 Quanser Inc. All rights reserved. NI ELVIS is a trademark of National Instruments. QNETs were developed by Quanser exclusively for National Instruments.
Review the following recommendations before contacting Quanser's technical support engineers
The External +24V LED is active as soon as the external power is connected to the QNET
Mechatronic Actuators. The ELVIS +5V, User and Status LEDs require that the NI ELVIS II
prototyping board is powered. Make sure both the System Power switch, which is
located on the back of the NI ELVIS II unit, and the Prototyping Board Power switch,
which is situated on the top-right corner of the NI ELVIS II, are ON.
Ensure the QNET Mechatronic Actuators power jack on the QNET Mechatronic Actuators
is connected with the supplied QNET Mechatronic Actuators power cable.
If the LED is still not lighting up, check the 2.5 A fuse of the QNET Mechatronic Actuators
next to the power jack. If it is burnt, replace it with an identical fuse. See the QNET
Mechatronic Acutators User Manual for more details.
If the ELVIS +5V LED is not lit then the internal resettable fuse on the NI ELVIS II may
have tripped. Try turning off the Prototyping Board Power switch and turning it back on.
If the ELVIS +5V LED still does not illuminate, then the QNET Mechatronic Actuators may
have an internal fault and will need to be returned for servicing.
For further assistance from a Quanser engineer, contact us at tech@quanser.com
or call +1-905-940-3575.
For full range of QNETs visit www.ni.com/quanser.
For advanced control tools for teaching and research, visit www.quanser.com