1. INSTALLATION AND WIRING
5. Apply adhesive to the ground terminal after fastening the terminal screw.
6. Secure the ground wire to the ship's ground.
The figures shown below are examples for grounding.
Ex.1
Ground wire
7. Secure the cable assembly to the cable cover with the cable ties (local supply) as
shown in the figure below.
If the cable is run through a
If the cable is run through a
radar mast and the bottom of the
radar mast and the bottom of the
unit, fix the cable to this cable
unit, fix the cable to this cable
clamp.
clamp.
8. Reattach the cable cover.
9. Connect the LAN connector of the cable assembly to a LAN port on the FURUNO
Multi Function Display or Ethernet HUB.
Note 1: Do not connect the LAN connector to on-board LAN.
Adhesive
Hex. bolt
Flat washer
Flat washer
Spring washer
Hex. nut
Fix the cable to this cable
Fix the cable to this cable
clamp, using a cable tie.
clamp, using a cable tie.
Power/LAN cable
Power/LAN cable
Cable cover - bottom view
12
Adhesive
Ex.2
Adhesive
Ground wire
Weld here.
Cable assembly
Cable assembly
Ground wire from
Ground wire from
the antenna unit
the antenna unit
Hex. nut
Spring washer
Flat washer
Hex. nut
Ground wire from
Ground wire from
the ship's ground
the ship's ground