unit with electronic regulation,
double heat exchanger and
adjustable tail pieces
The GE556Y413 and GE556Y416 heat interface units (HIU) allow the metering of heat energy consumption for heating and
the production of DHW (Domestic Hot Water) in modern autonomous systems with centralised heat production (e.g. district
heating).
The configuration with two heat exchangers in parallel provides the following advantages:
• parallel and non-intermittent handling of the domestic hot water and heating functions;
• higher safety, the heating circuit is a sealed pressurised system should there be any leaks within property only a small
amount of water will be discharged.
The management of the HIUs parameters is completely electronic.
This allows significant energy savings, minimizing the flow demand from the primary side and reducing the return temperature.
The various parameters can be set via remote control which also performs the function of programmable chronothermostat.
Giacomini S.p.A.
Via per Alzo 39, 28017 San Maurizio d'Opaglio (NO) Italia
 consulenza.prodotti@giacomini.com
 +39 0322 923372 - giacomini.com
Datasheet/Instruction
1062EN  11/2021
047U59118
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GE556-6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Giacomini GE556-6

  • Page 1 This allows significant energy savings, minimizing the flow demand from the primary side and reducing the return temperature. The various parameters can be set via remote control which also performs the function of programmable chronothermostat. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 2: Completion Codes

    • Safety pressure switch for low pressure on the primary side. • Heat exchanger and fully insulated piping. • Painted sheet metal cabinet (RAL9010), with key locking. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 3 Domestic cold water inlet Domestic cold water outlet Domestic hot water outlet Primary inlet Primary outlet Heating return Heating delivery Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 4 3) Shut-off ball valve to isolate the HIU 4) Joint that allows the connection from above and from below 5) System pipes, Ø 22 mm Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 5: Operation

    Minimum pressure switch Temperature probe Flow switch Check valve Brass spacer for thermal energy meter Brass spacer for water meter Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 6 The DHW circuit consists of a flow switch, a check valve on the DCW inlet and two brass spacers for the introduction of the water meters. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 7  NOTE. For the other operating modes of the remote control, refer to the corresponding instruction sheet. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 8: Preheating Function

    °C 4/10 Screed heating timing final phase days  NOTE. To enable parameter programming, please refer to the remote-control manual. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 9 Sluggish motor, pump is operated outside of its Overload specifications (e.g. high module temperature). The speed is lower than during normal operation Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 10: Electrical Connections

    • The optional safety thermostat (K373/K373I), is connected to terminals 39-40 of the electronic board. • Multizone additional control to terminals 21-22 on the electronic board (additional thermostats to be ordered separately). Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 11 Complete the installation by tightening the HIU nuts on the template connections (max. torque 60 Nm) using a backup spanner. Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 12 [l/h] [kW] [°C] [l/h] [°C] Diagram of the heating circulator - Circulator at constant ∆p 1100 MAX. 1400 24,5 1350 Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 13 [°C] [l/h] [°C] 18,5 21,5 0,10 20,5 0,01 10,0 Q [m Hydraulic data for domestic water circuit 1020 47,5 1200 Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 14 8,2 kW ∆T (40-45 °C) Q=1400 l/h 8,2 kW ∆T (30-35 °C) Q=1400 l/h T primary delivery [°C] Low temperature Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 15 [l/h] [kW] [°C] [l/h] [°C] Diagram of the heating circulator - Circulator at constant ∆p 1100 MAX. 1400 24,5 1350 Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 16 Hydraulic data for domestic water circuit 1020 47,5 23,5 1020 25,5 22,5 1200 23,5 1050 24,2 1320 61,5 1040 1160 24,6 1030 1440 1150 1280 Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 17 8,2 kW ∆T (40-45 °C) Q=1400 l/h 8,2 kW ∆T (30-35 °C) Q=1400 l/h T primary delivery [°C] Low temperature Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 18 Domestic cold water outlet Heating delivery Domestic hot water outlet Fairleads Primary inlet Hole for safety valve drain Primary outlet Dimensions in mm Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 19: Reference Standards

    • ErP Directive 2009/125/CE  WRAS certification REF. IN “COMPONENTS” PARAGRAPH COMPONENT CERTIFICATE NUMBER Gaskets 1509514 Flow switch 1605300 5, 16 Heat exchanger 1909083 Giacomini S.p.A. Via per Alzo 39, 28017 San Maurizio d’Opaglio (NO) Italia  consulenza.prodotti@giacomini.com  +39 0322 923372 - giacomini.com...
  • Page 20 Umwelt oder die illegale Entsorgung des Produkts ist strafbar.  Safety Warning. Installation, commissioning and periodical maintenance of the product  Additional information. For more information, go to giacomini.com or contact our technical must be carried out by qualified operators in compliance with national regulations and/or local assistance service.