Technical Specification; Electrical Connection (U.k. Only) - DeLonghi Pinguino FX140ECO Use And Maintenance Manual

Table of Contents

Advertisement

FX160/400ECO GB
24-06-2004
FX160 ECO
OPERATING LIMITS
Room temperature
FX400 ECO
OPERATING LIMITS
Room temperature
Outside temperature
A) If your appliance comes fitted with a plug, it will incorporate a 13 Amp fuse. If it does not fit your socket, the plug should
be cut off from the mains lead, and on appropriate plug fitted, as below. warning: Very carefully dispose of the cut off
plug after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a moulded-
on type, the fuse cover must be re-fitted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nea-
rest electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B) If your appliance is not fitted with a plug, please follow the instructins provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with
the following code:
Green and yellow Earth
Blue
Brown
11:55
Pagina 35

Technical specification

21 - 35°C
21 ÷ 32°C
21 ÷ 43°C

ELECTRICAL CONNECTION (U.K. ONLY)

As the colours of the wires in the mains lead may not corre-
spond with the coloured markings identifying the terminals
in your plug, proceed as follows:
The green and yellow wire must be connected to the termi-
nal in the plug marked with the letter E or the earth symbol
Neutral
E
The blue wire must be connected to the terminal marked with
Live
the letter N or coloured black.
L
The brown wire must be connected to the terminal marked
N
with the letter L or coloured red.
TECHNICAL SPECIFICATION
Power supply
Max. absorbed power
in air conditioning
Max. absorbed power
when dehumidifying
Refrigerating capacity*
Number of fan speeds
Max. air flow
Dimensions of internal unit:
• width
• height
• depth
• weight
Dimensions of external unit (only FX400 eco):
• width
• height
• depth
• weight
*
Standard conditions:
Room temperature
47% relative humidity
Outside temperature
41% relative humidity
or coloured green or green and yellow.
see rating plate
"
"
"
2 + silent
460 m
3
/h
452 mm
800 mm
455 mm
33 kg
570 mm
480 mm
260 mm
18 kg
27°C
35°C
35