Machine Size

A
1055(42)
Usage: Tamping rammer is designed to deal with adhesive soil, sand, and granular compaction,
but not suitable for hard concrete surface or earth ground. The electrical tamping rammer is
suitable for works, especially, in an emission and noise forbidden area.
Power connection: To reduce electric shock risks, all four-line plugs and sockets and extension
cables must have a ground line.
1..1 Keep the starter switch at OFF before power connection.
1..2 Check if voltage of power source matches the rated or not. A lower voltage supply
slows down the compaction speed, degrades machine's function, and causes motor
overheating.
1..3 To protect the operator from an electric shock, the machine must have a ground line
connection. All Masalta electric rammers are equipped with a four-line cable and
socket, the line of yellow and green color is for the ground connection.

Power cable application

If an extension cable is required during an operation, the cable size should be large enough
to carry machine's rated load, for poor load-carrying cable lowers down the voltage and then
overheats the closed circuit, which may cause a serious fire accident and danger.
Specification of the cable depends on its length. Any doubts about this, choose the big
enough one as an option. And, it is not allowed to use old or worn cables.